22
1. S
pecification
s Che
ck
[3] Motor straight type
(Note) High-output settings are not available in RA8C or RA8R that operate with the PCON-CFB
controller.
[When high-output setting is ineffective]
Speed limits [Unit: mm/s]
Stroke [mm]
Type
Motor
Type
Lead
[mm]
Horizontal/
Vertical
50 100
150
200
-
-
Horizontal
130
-
-
2.5
Vertical 130
-
-
Horizontal
260
-
-
5
Vertical 260
-
-
Horizontal
525
-
-
10
Vertical 525
-
-
Horizontal
560
-
-
RA4C 35P
16
Vertical 560
-
-
50
100
150
200
250
300
Horizontal
125
3
Vertical 125
Horizontal
250
6
Vertical 250
Horizontal
500
12
Vertical 500
Horizontal
640
RA6C 42P
20
Vertical 640
50
100
150
200
250
300
Horizontal
105
4
Vertical 105
Horizontal
210
8
Vertical 210
Horizontal
420
16
Vertical 280
Horizontal
600
RA7C 56P
24
Vertical 400
Summary of Contents for RCP6
Page 2: ......
Page 8: ...1 ...
Page 79: ...72 2 Installation RA8 Stroke 185 5 Maximum Stroke 70 5 Minimum 15 ...