100
5.
Maintena
nce and Inspe
ctio
n
3) Make the profiles on the actuator side and motor unit side aligned so the projection matches to
the slit.
4) Attach the motor unit for replacement with the projection being matched with the slit.
5) Tighten the fixing screw to affixing the motor unit to the actuator with 2mm-sized (RA4C,
RA6C) or 2.5mm-sized (RA7C) hexagonal wrench.
Model Tightening
Torque
RA4C, RA6C
167N cm
RA7C 353N
cm
6) Make sure to conduct a home return on a PC or a touch panel teaching after motor
replacement.
Make the projection and slit
matched with each other.
Apply grease to the coupling part.
NOXLUB TL1010 grease made by NOK
For Fixed screws actuator and
Motor Unit
Summary of Contents for RCP6
Page 2: ......
Page 8: ...1 ...
Page 79: ...72 2 Installation RA8 Stroke 185 5 Maximum Stroke 70 5 Minimum 15 ...