115
6. Extern
al
Dim
ensi
on
s
6.5 Standard Specification RCP6-RA7C
ST : Stroke
M.E. : Mechanical End
S.E. : Stroke End
L Mass
[kg]
Stroke
W/o
Brake
With
Brake
A
W/o
Brake
With
Brake
50 354.5
404.5
214.5
4.5 4.9
100 404.5
454.5
264.5
5.1 5.5
150 454.5
504.5
314.5
5.6 6.0
200 504.5
554.5
364.5
6.2 6.6
250 554.5
604.5
414.5
6.7 7.2
300 604.5
654.5
464.5
7.3 7.7
(Note)
L dimensions described in the table are those with no cable exit direction (option).
For cable exit
direction types (option), the dimensions are longer in 25mm.
Enclosed
hexagonal nut
Greasing Port
(ø5 hole)
Home
4-M8 Depth 16
The angle of the width
across flat is undefined.
Greasing Port (ø5 hole)
(The same applies to
the other side)
CJR
Right
CJB
Bottom
2-M3 Depth 6
(For ground
connection)
M14X1.5
Cable Exit Direction (Optional)
140 (W/o Standard Brake)
190 (With Standard Brake)
Detailed View P
Scale 1 : 1
2-M3 Depth 6
(For ground
connection)
Disabled
when CJL
is selected.
Disabled
when CJR
is selected.
Maintain it more
than 100
M14X1.5
CJT
Top
CJL
Left