6
7. Installation
7.1 Installing the Main Body
As a rule, the actuator should be installed in a horizontal position. Do not install it in a slanted or vertical
position with the motor located at the bottom. The mechanical oil sealed in the pipe may leak out and
cause failures.
The base plates on both ends of the actuator have through holes. Use these holes when installing the
actuator.
For installation, refer to the table below and use hexagon socket-head bolts of the specification
appropriate for the material of the frame on which the actuator is installed.
Steel frame
Aluminum frame
M8 x 100
M8 x 110
Use of high-tensile bolts conforming to ISO 10.9 or greater is recommended.
Recommended torque is 14 N
⋅
m (1.43 kgf
⋅
m).
4-9 bore,
∅
14 deep, counterbore depth 10
Horizontal position