5
6. Operating
and
Storage Environment
6.1 Operating
Environment
The actuator should be set up in an environment, which meets the following criteria:
•
Avoid direct sunlight.
•
Avoid radiant heat from strong heat sources such as a furnace.
•
Surrounding air temperature should be 0 ~ 40
°
C.
•
The atmosphere is free from corrosive gases, combustible gases, combustible dust particles, flammable
liquids, etc.
•
The actuator will not receive impact or vibration exceeding 0.3 G.
•
Avoid extreme electromagnetic waves, ultraviolet rays and radiation.
•
Sufficient space is available that allows teaching, maintenance or inspection to be performed safely.
•
The actuator will not be immersed in liquid.
•
The atmosphere is free from cutting oil.
•
The atmosphere is free from mist of sulfur-containing cutting fluid, grounding fluid, etc.
* Contact IAI for the actuator’s splash-proof performance against liquids other than water.
6.2 Storage
Environment
Store the actuator in an environment meeting the same conditions specified for the installation
environment. If the actuator will be stored for an extended period of time, take appropriate measures to
prevent bedewing.
Unless otherwise specified by the customer, the actuator is shipped without any drying agent placed in the
package. If you anticipate bedewing in your storage environment, provide anti-bedewing measures over
the shipping box or directly onto the actuator inside the box.
During storage, the actuator can withstand temperatures of up to 60
°
C for a short period. If the actuator
will be stored over one month, keep the surrounding air temperature to 50
°
C or below.