background image

 Working version

Summary of Contents for Robin MiniMe

Page 1: ... Working version ...

Page 2: ...iniMe 8 3 4 DMX 512 connection 10 3 5 Ethernet connection 11 4 Control menu map 12 5 Control menu 14 5 1 Addressing DMXA 14 5 3 Personality Pers 15 5 4 Manual Control Manual 15 5 5 Stand alone St Alone 15 5 7 User Media User Media 16 6 Keystones 17 7 Error and information messages 18 8 Technical Specifications 18 9 Maintenance and cleaning 21 Robin MiniMe Robin MiniMe ...

Page 3: ...lling the fuses or any part The power plug has to be accessible after installing the fixture Do not overload wall outlets and extension cords as this canresult in fire or electric shock Do not allow anything to rest on the power cord Do not locate this fixture where the cord may be damaged by persons walking on it Make sure that the power cord is never crimped or damaged by sharp edges Check the f...

Page 4: ...t block the front objective with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 20 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional oper...

Page 5: ...re exterior view 6 DMX Out 5 pin XLR 7 DMX In 5 pin XLR 8 Ethernet RJ45 9 2x USB input 10 HDMI input 11 Power Input 12 Power output 1 Moving head 2 Arm 3 Base 4 Attachment point for safety cable 5 Control board ...

Page 6: ...about proper installation consult a qualified electrician Core EU Core US Connection Plug Terminal Marking Brown Black Live L Light blue White Neutral N Yellow Green Green Earth This device falls under class one and must be earthed grounded Design of the Robin MiniMe allows to connect several fixtures to AC mains power in one interconnected daisy chain using power input and throughput connectors N...

Page 7: ... EXPERIENCE including calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but use a help of professional companies CAUTION Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible ins...

Page 8: ...ection in the menu Personality Pers LED Engi Ceil P On 3 Rear Table the fixture is placed near the floor behind the screen Set Rear Projection in the menu Personality Pers LED Engi Rear P On Note that a special rear projection screen is required 4 Rear Ceiling the fixture is suspended upside down from the ceiling truss behind the screen Set Rear Projection in the menu Personality Pers LED Engi Cei...

Page 9: ...nd that if you intend to permanently install the Robin MiniMe you should physically test the projection size and distance using the actual fixture before you permanently install it There is a chart of throw distance ratio of 3 5 1 to assist you in determining the ideal location for your fixture ...

Page 10: ...re in the DMX chain If you wish to connect DMX controllers with other XLR out puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Up to 32 fixtures can be interconnected Caution At the last fixt...

Page 11: ...o the network RJ 45 socket front view RJ 45 plug front view 1 TD 5 Not connected 2 TD 6 RX 3 RX 7 Not connected 4 Not connected 8 Not connected Patch cables that connect fixtures to the hubs or LAN sockets are wired 1 1 that is pins with the same numbers are connected together 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 If only the fixture and the computer are to be interconnected no hubs or other active comp...

Page 12: ...000 255 ArtN Uni 000 255 000 255 Info POn Time Total Reset DMX In Pan 0 255 Dimmer 0 255 Temp CPUt Head Sw Ver GE IC 1 Pers Pan Rev On Off Tilt Rev On Off P T Mode Speed Time P T Feed On Off BLC DMC On Off P T Mov On Off Display Turn On Off T On Off Contrast 0 15 Backlight 0 15 LED Engi Ceil P On Off Reir P On Off Ref Rate 50 Hz 60 Hz Fans Auto High I Ef Pos Pan Dimr Store Defaults Manual DMX Ctrl...

Page 13: ...6 Level 7 St Alone Auto Run Play Off DMX Prg 1 DMX Prg 9 Pl DMX Prg DMX Prg 1 DMX Prg 9 Rc DMX Prg DMX Prg 1 DMX Prg 9 Reset Reset GE Reset P T Reset Focu Reset All User Media No USB Delete Int Me Special Cali Pan C Tilt C Focu C Gamma C Sw Upd Hw Upd ...

Page 14: ...o the controller If you set for example the address 23 the Robin MiniMe will use channels 23 54 for control Please be sure that you do not have any overlapping channels in order to control each Robin MiniMe correctly and indepen dently from any other fixture on the DMX data link ArtN Uni Set ArtNet Universe Use this menu item to set desired ArtNet Universe Note If default values are loaded from th...

Page 15: ...ontrast Use this function to adjust contrast of the display 0 15 Backlight Use this function to adjust backlight of the display 0 15 LED Engi Led engine options Enter the menu if you want to set special options for LED engine Ceil P Ceiling projection When this function is On a picture is top bottom and left right reversed This function enables to project the image from a ceiling mounting of the M...

Page 16: ...cture may be also created by means of your computer but exactly the same names and small letters have to be kept The media files should follow the 3 digit conventions where a 3 digit number is followed by an underscore and a name e g 001_testfile1 jpg 002_landscape jpg Max number of media files in folder is 250 The images can be in jpg format 1280x800 max and the videos in mpeg4 or avi format Mirr...

Page 17: ... is 128 it means that no keystone correction has been used The keystone values can also be used to create interesting skewing effects The option Save AutoKeystoning from DMX chart channel Special functions range 230 234 allows to save adjusted values of the keystone channels and correct them automatically when head position is changed First use the Keystoning Vertical channel and the Kyestoning Ho...

Page 18: ...ons Electrical Power supply electronic auto ranging Input voltage range 100 240V 50 60Hz Fuse T 3 15A 250V Power consumption 100W 230V I 0 43A power factor 0 87 Allow for a deviation of 10 Light Engine Light source RGB LED device Light output 300 ANSI lumens Rated light source life 20000 hours Digital Gobo Image Projection Output Aspect ratio 16 10 Resolution WXGA 1280x800 Throw ratio 3 5 1 Contra...

Page 19: ...rt Art Net ready for ACN External Wireless DMX RDM module optional Compliance with USITT DMX 512 1986 1990 and 512 A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size 5ms DMX latency Operational frequency range of 2402 2480 MHz Producer LumenRadio Connection DMX data in out Locking 5 pin XLR 2 x USB 2 0 connector series A ArtNet RJ 45 Neutrik Ethercon External vid...

Page 20: ...7 Robe Wireless CRMX LB100 P N1305 1731 Mains Cable PowerCon In open ended 2m P N 1305 1724 Mains Cable PowerCon In Schuko 2m P N 1305 1725 Mains Cable PowerCon In CEE 16A 2m P N 1305 1726 Mains Cable PowerCon In US 2m P N 1305 1727 Daisy Chain PowerCon In Out EU 2m P N 1305 1728 Daisy Chain PowerCon In Out US 2m ...

Page 21: ...ar cleaning will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used The front lens may require monthly cleaning as smoke fluid tends to building up residues reducing the light output very quickly ...

Page 22: ...22 ...

Reviews: