6
3. Installation
Fixtures must be installed by a qualified electrician in accordance with all
national and local electrical and construction codes and regulatio
n.
3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The Robin MiniMe is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240 Volts.
Install a suitable plug on the power cord, note that the cores in the power cord are coloured according to the
following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green
Earth
This device falls under class one and must be earthed (grounded)!
Design of the Robin MiniMe allows to connect several fixtures to AC mains power in one interconnected daisy
chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specifications “
The max. number of connected fixtures depends on the AC mains power voltage:
23 fixtures at power supply= 230V
19 fixtures at power supply= 208V
11 fixtures at power supply= 120V
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualified staff!