robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thellle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
VALID SINCE
: 25.06.01
10
DOSSIER TECHNIQUE
HMI PROFILE 1200W & 2500W
DocT
ech_900SNX_0601.ind
900 SNX
B
e
A
h
C
g
f
Each time you switch on: make sure
the fans are working correctly.
Lighting unit / Power supply connection.
- Connect the lamp cable C to the connector 7 of the
ballast and connector e to the lighting unit.
- Connect the cable D to the connector ( d ) of the
ballast and to the connector f of the lighting unit "XLR7".
- Place the lamp into position - refer to page 12.
- Connect the DATA line on connector ( a ) "XLR5" or
the analog command to the the connector ( c ) "XLR4".
( For the connection configurations : refer to page 20 ).
- Connect the optional units that are possible, to connector g
( Only DATA ).
- Plug the cable 8 to the mains. If the power is present, the
checklight 1 lights up immediately.
- Engage the circuit breaker 3 and check that the CAD 900
protection 4 is well engaged.
- If you use the optional outlet 5 , engage the circuit breaker 2 .
- Lock the cable C in the clips i .
WARNING !
- Never open the lantern's bonnet when the lighting unit is on.
- Do not change the safety switches.
- Never connect to a dimmable channel.
- Use only when bulb is in place.
A 900 SNX Motorized shutter - CAD 900 version.
e
- EM HARTING 16 x 16A power socket.
f
- EM XLR7 s DATA (option).
g
- EF XLR5 output DATA (colour changer option).
h
- EF mains output 220/240V (colour changer option).
B Power supply unit.
1
- Mains checklight.
2
- UNI + N 2A-C automatic breaker.
3
- General 16A circuit breaker for
HMI 1200
.
General 25A circuit breaker for
HMI 2500
.
4
- UNI + N 2A-C automatic breaker.
6
- Ventilation opening
(DON'T OBSTRUCT THE AIR GAPS).
7
- EF HARTING 16 x 16A - 2 latch connector.
8
-
Mains cable 3G x
1
,5
mm (
3
m)+FM 10/16A.(
HMI 1200
).
Mains cable 3G x
4mm (
3
m)+FM P17 2P+T 32A.(
HMI 2500
).
9
- CAD 900 local controls.
10
- Rating plate.
11
- Power supply selector :
208V. 60Hz, 230V. 50Hz & 245V. 50Hz.
Position locked by a screw.
C Lamp cable.
Cable H07 RN-F 19G1,5 mm length 3m fitted
with 16 x 16A M/F HARTING connectors.
D Shutter cable.
14 conductors reinforced shielded cable - length 3m
fitted with XLR7 M/F connector.
ERROR
DATA
EXT. DIGI.
EXT.
LOCAL
LOCK
SELECT
EXIT
+
CONTROL
SHUTTER
DATA
0/10V
0/10V - DMX 512 - AVAB
C A D 900
RESET
a b c d
a - EM XLR5 : DATA input.
b - EF XLR5 : DATA output.
c - EM XLR4 : 0/+10V. input.
d - EF XLR7 : lighting unit output.
DATA out.
DATA in.
DESCRIPTION.
CONNECTIONS.
0/+10V. line.
OPTION
DMX colour
changer.
Mains voltage.
- Check the conformity of the power supply unit.
Rating plate 10 : Lamp power.
Summary of Contents for SNX 900 Series
Page 2: ...NOTES...