robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thellle phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
VALID SINCE
: 25.06.01
42
DOSSIER TECHNIQUE
HMI PROFILE 1200W & 2500W
DocT
ech_900SNX_0601.ind
900 SNX
3.3. The off command is given, but the lamp
stays on.
message unchanged.
4 . NON-FUNCTIONING DIAGNOSIS FOR THE SHUTTER :
1.1 The shutter command is given, but no
action.
1.2 . The shutter only excepts an up command,
does not except an down command.
resend the
level
command.
New shutter level
displayed.
Shutter cable demaged :
Check cable.
Faulty power supply :
Change CAD :
( Refer to Tech. File - page 35 )
The shutter does
not react or reacts
badly.
Motor demaged : Change the
whole shutter unit.
( refer to Tech. File - page 32)
1.3 . The shutter reacts badly, and the motor
runs continuous.
1.4. The shutter act in a saw-tooth movement
on a fluent command.
1.5. Shutter action is delayed to command.
The shutter level is
correctly displayed.
Error on the Shutter unit :
Change the whole shutter unit.
( refer to Tech. File - page 32 )
Green &
red LED :
off
Transmission Data error :
connection failure : check the wiring.
( refer to Tech. File p. 10 & 20).
connection damaged or :
( refer to Tech. File p. 10 & 20 ).
message unchanged.
Resend the
"LAMP OFF"
command.
New shutter level
not displayed.
Command link error :
Digital - refer to 3.1.
Analog - refer to 2.
Green &
red LED
on.
Resend the
"LAMP OFF"
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.
resend the
level
command.
Summary of Contents for SNX 900 Series
Page 2: ...NOTES...