background image

Gas leakage 
(odor of gas)

Abnormal 

combustion 

or noises

Close the switch knob

Connect the hose properly or replace it

The switch knob is not closed

The hose is not proper connected 
or has cracks

Faults

Ignition failure

Flame extinct 

after releasing

Solutions

Close the switch knob of stove and then open
 the valve of gas source

Carry out ignition repeatedly to exhaust the air 
in pipe

Straighten, unblock or replace the hose

Clean the head

Adjust the distance between the ignition 
electrode and the receiving end at around 
4 mm

The cooper core and cooper cap must be put 
in place

Narrow down the throttle

After ignition, hold and press the switch knob 
for 3~5 seconds (to the maximum extend) and
then release it

Causes

The cooper core and cooper cap are 
not in place

The knob is not pressed to the 
maximum extend

Bending, blocking or pressing of hose

Air in gas pipe

The switch of gas source closes

The porcelain head of ignition electrode
 is not clean

Improper distance between the ignition 
electrode and the receiving end

The throttle is so wide that causes lifted 
flame

 

1.

       

Instruction book 

 2.Installation templet      

3.One battery            

4.Clamps 2 (excluding the products with metal hose)

Accessories

8

Gas Hob

Common Faults and Solutions

No battery, wrong battery installation or 
insufficient electric power

Correct install the battery or replace it with a 
new one

Improper adjustment of throttle

Blockage of burner or flame outlet

The gas used is not in consistence 
with the gas type marked on stove

Unstable gas pressure, water in hose

Adjust the throttle

Remove the blockage

Select correct stove

Remove the water in hose

Switch

Pan

 

Stand

Copper

 

Core

Copper

 

Cover

Aluminum Base

Electrode

 

Needle

Thermocouple

Burner

water pan

1

2

3

Summary of Contents for JZT-B920

Page 1: ...Operation Manual JZ Y T B920 Gas Hob...

Page 2: ...Precautions Product introduction Product Features Performance Parameters Operation Methods Common Faults and Solutions Accessories Product Structure Installation Instruction Clean and Maintenance 1 4...

Page 3: ...harm or property damage to the users and other persons following distinctions and signs are specially given All these are the important notices concerned with safety so please abide by these notices s...

Page 4: ...s provided randomly In the meantime leakage detection shall be carried out to make sure there is no leakage After that the product can be used If gas leakage is observed the valve of the gas source sh...

Page 5: ...carefully and gently so as to avoid damage on the panel During using or igniting if awhirring sound that indicates the flareback of burner is heard the switch knob of the stove shall be closed immedi...

Page 6: ...t installation 5 Tempered glass with anti explosion net is adopted as the glass panel of gas stove which is safe durable and easy to clean Product introduction Dear users We take this opportunity to e...

Page 7: ...r end shall be connected with the gas inlet of the gas stove Note Please remove the protective cap on the joint The hose ends shall cover the red marks and secured by the clamps provided randomly In t...

Page 8: ...fore repeat operations are required 3 Flame out Rotate the switch knob clockwise to the Fig 1 location for flame out 4 Flame adjustment Rotate the switch knob according to its flame indication to obta...

Page 9: ...ts regularlyfor any displacement or deviation and carry out rectification accordingly to put them in place so as to avoid the occurrence of accident Flame port on cooper core Ignition groove Inner rin...

Page 10: ...it Causes The cooper core and cooper cap are not in place The knob is not pressed to the maximum extend Bending blocking or pressing of hose Air in gas pipe The switch of gas source closes The porcela...

Page 11: ...Edition A 0 Publication Date March 1 2017...

Reviews: