Prohibited

Do  not  use  baffler  to  cover  the  flame.  Putting  inflammables  around  stove  and  drying 
towels, clothes, etc. with stove are not allowed. 

During  ignition,  please  keep  head  away  from  the  burner.  After  using,  please  close  the 
valve  of  the  gas  source  and  the  switch  knob  of  the  gas  stove,  so  as  to  avoid  the 
occurrence of accident. 

The  cupboard  where  an  embedded  gas  stove  is  going  to  be  installed  shall  have  an 
atmosphere-connected  opening  that  satisfies  ventilation  requirements  (with  an  area  no 

2

less than 100 cm ), so as to avoid explosion caused by deposited leaked gas. 

Please do not turn on the stove without putting any pot or use it to heat any empty pot, as 
such  operation  may  damage  the  extractor  hood  due  to  excessive  heating  or  ignite  the 
greases on extractor hood and cause fire disaster. 

During  and  short  after  using,  please  do  not  touch  areas  like  pot  rack,  burner  cap  and 
stove panel as they are still hot. 

2

If special gas hose is adopted, one end of the hose shall be connected with the valve of 
gas source and the other end shall be connected with the gas inlet of the gas stove (Note: 
Please remove the protective cap on the joint). The hose ends shall cover the red marks 
and secured by the clamps provided randomly. In the meantime, leakage detection shall 
be carried out to make sure there is no leakage. After that, the product can be used. 

If  gas  leakage  is  observed,  the  valve  of  the  gas  source  shall  be  closed  immediately  and 
window shall be opened for ventilation. Exhausting gas with electric fan, extractor hood or 
other  electric  appliances  is  not  allowed.  Do  not  operate  the  switch  of  any  electric 
appliance and no fire is allowed. In the meantime, please contact the after-sales service 
of the local branch. 

Gas Hob

If  anti-drop  metal  hose  is  adopted,  the  hose  must  be  installed  as  per  the  methods  and 
steps  specified  in  the  operation  instruction  in  the  package  of  the  hose  strictly  (by  the 
professional  staff  of  the  Company)  and  leakage  detection  must  be  carried  out  (See  the 
methods above). 

Danger

No touch

Prohibited

Abide by 

strictly

Abide by 

strictly

Abide by 

strictly

Abide by 

strictly

Abide by 

strictly

Do not screw the hold-down nut at the joint of the gas inlet without permission. If the nut is 
screwed for wrong joint direction, leakage detection must be carried out at the site 
(Methods: Apply a thin layer of neutral cleaning solution on the joint and open the valve of 
gas source to heck if there is any bubble. If bubble is observed, close the valve and screw 
down the nut. Carry out leakage detection again to make sure there is no leakage. After 
that, the product can be used.) 

Abide by 

strictly

Switch

Pan

 

Stand

Copper

 

Core

Copper

 

Cover

Aluminum Base

Electrode

 

Needle

Thermocouple

Burner

water pan

1

2

3

Summary of Contents for JZT-B920

Page 1: ...Operation Manual JZ Y T B920 Gas Hob...

Page 2: ...Precautions Product introduction Product Features Performance Parameters Operation Methods Common Faults and Solutions Accessories Product Structure Installation Instruction Clean and Maintenance 1 4...

Page 3: ...harm or property damage to the users and other persons following distinctions and signs are specially given All these are the important notices concerned with safety so please abide by these notices s...

Page 4: ...s provided randomly In the meantime leakage detection shall be carried out to make sure there is no leakage After that the product can be used If gas leakage is observed the valve of the gas source sh...

Page 5: ...carefully and gently so as to avoid damage on the panel During using or igniting if awhirring sound that indicates the flareback of burner is heard the switch knob of the stove shall be closed immedi...

Page 6: ...t installation 5 Tempered glass with anti explosion net is adopted as the glass panel of gas stove which is safe durable and easy to clean Product introduction Dear users We take this opportunity to e...

Page 7: ...r end shall be connected with the gas inlet of the gas stove Note Please remove the protective cap on the joint The hose ends shall cover the red marks and secured by the clamps provided randomly In t...

Page 8: ...fore repeat operations are required 3 Flame out Rotate the switch knob clockwise to the Fig 1 location for flame out 4 Flame adjustment Rotate the switch knob according to its flame indication to obta...

Page 9: ...ts regularlyfor any displacement or deviation and carry out rectification accordingly to put them in place so as to avoid the occurrence of accident Flame port on cooper core Ignition groove Inner rin...

Page 10: ...it Causes The cooper core and cooper cap are not in place The knob is not pressed to the maximum extend Bending blocking or pressing of hose Air in gas pipe The switch of gas source closes The porcela...

Page 11: ...Edition A 0 Publication Date March 1 2017...

Reviews: