Cut a hole in the worktop that corresponds with the relevant drawing on the previous page.
◆
appliance and any
surface that is below it.
◆
IMPORTANT
: Do not use a silicon sealant to seal the appliance against the aperture. This will make it
difficult to remove the hob from the aperture in future, particularly if it needs to be serviced.
◆
The
minimum
clearance
from
a
combustible
surface
shall
be
a
200
mm
horizontal
distance
from the
periphery
of
any
gas
burner
(
AS
/
NZS
5601.1).
IMPORTANT
:
You
must
have
a
gap
of
at
least
50
mm
between
the
underneath
of
the
5
47
mm
50
mm
Gas
Hob
Important information
◆
◆
Failure to install the appliance correctly could invalidate ROBAM APPLIANCES CO.,LTD. guarantee and
lead to prosecution under the regulations quoted above.
◆
An AUTHORISED PERSON undertake the installation and service work, in compliance with the above
regulations.
The hob must be installed by a qualified person, in accordance with the current edition of the gas safety
(Installation and use) (amendment) regulations and the relevant building/I.E.E. regulations.
Ventilation requirements
◆
The room containing the hob should have an air supply in accordance with the current edition of AS/NZS.5601.1
◆
The room must have opening windows or equivalent; some rooms may also require a permanent vent.
◆
If the room has a volume between 5 and 10m³, it will require an air vent of 50cm²(effective area). Unless it
has a door which opens directly to the outside.
◆
If the room has a volume of less than 5m³, it will require an air vent of 100cm²(effective area).
◆
If it is installed in a room with a volume that exceeds 11m³, then no air vent is required.
◆
If there are any other fuel burning appliance in the same room the current edition of AS/NZS 5601.1 should
be consulted to determine air vent requirements.
◆
Ensure that the room containing the hob is well ventilated, keep natural ventilation holes or install a
mechanical ventilation device(mechanical cooker hood).
◆
Prolonged intensive use of the appliance may call for additional ventilation, either by the opening of a
window
,
or
by
increasing
the
level
of
the
mechanical
ventilation
device(where
present).
◆
This hob is not fitted with a device for discharging the products of combustion. Ensure that the ventilation
rules and regulations are followed.