background image

Cut a hole in the worktop that corresponds with the relevant drawing on the previous page.

appliance and any

   surface that is below it.

IMPORTANT

: Do not use a silicon sealant to seal the appliance against the aperture. This will make it

difficult to remove the hob from the aperture in future, particularly if it needs to be serviced.

The

 

minimum

 

clearance

 

from

 

a

 

combustible

 

surface

 

shall

 

be

 

a

 200 

mm

 

horizontal

 

distance

 

from  the

periphery

 

of

 

any

 

gas

 

burner

 (

AS

/

NZS

 5601.1).

IMPORTANT

 :

You

 

must

 

have

 

a

 

gap

 

of

 

at

 

least

 50 

mm

 

between

 

the

 

underneath

 

of

 

the 

5

47

mm

50

mm

Gas

 

Hob

Important information

   

Failure to install the appliance correctly could invalidate  ROBAM APPLIANCES CO.,LTD. guarantee and

   lead to prosecution under the regulations quoted above.

An AUTHORISED PERSON undertake the installation and service work, in compliance with the above

regulations.

The hob must be installed by a qualified person, in accordance with the current edition of the gas safety

(Installation and use) (amendment) regulations and the relevant building/I.E.E. regulations.

Ventilation requirements

The room containing the hob should have an air supply in accordance with the current edition of AS/NZS.5601.1

The room must have opening windows or equivalent; some rooms may also require a permanent vent.

If the room has a volume between 5 and 10m³, it will require an air vent of 50cm²(effective area). Unless it

has a door which opens directly to the outside.

If the room has a volume of less than 5m³, it will require an air vent of 100cm²(effective area).

If it is installed in a room with a volume that exceeds 11m³, then no air vent is required.

If there are any other fuel burning appliance in the same room the current edition of AS/NZS 5601.1 should

be consulted to determine air vent requirements.

Ensure that the room containing the hob is well ventilated, keep natural ventilation holes or install a

mechanical ventilation device(mechanical cooker hood).

Prolonged intensive use of the appliance may call for additional ventilation, either by the opening of a

window

 ,

or

 

by

 

increasing

 

the

 

level

 

of

 

the

 

mechanical

 

ventilation

 

device(where

 

present).

This hob is not fitted with a device for discharging the products of combustion. Ensure that the ventilation

rules and regulations are followed.

Summary of Contents for JZT B110

Page 1: ...Use Manual Gas Hob JZY B110 JZT B110 JZY B310 JZT B310 JZY G311 JZT G311 JZY B410 JZT B410 JZY G411 JZT G411 JZY B510 JZT B510 JZY G511 JZT G511...

Page 2: ...12 Installation Instruction Clean And Maintenance Important Safety Information Technical Information Operation Methods 3 Substituting The Injectors 14 Contents Accessories 13 Circuit Diagram After Sal...

Page 3: ...UCTION BOOKLET BEFORE ATTEMPTING TO INSTALL OR USE THE APPLIANCE IF YOU ARE UNSURE OF ANY OF THE INFORMATION CONTAINED IN THIS BOOKLET PLEASE CONTACT THE ROBAM APPLIANCES CO LTD General Information Ge...

Page 4: ...e electrical connection cables to come into contact with the hob surface when it is hot or any hot cookware If fat and oil overheats then it can ignite extremely quickly For this reason when cooking w...

Page 5: ...le for any personal injury or property damage caused by AUTHORISED PERSON IN ACCORDANCE WITH THE CURRENTVERSIONOFTHEFOLLOWING FOR AP LIANCE INTENDED FOR USE WITH A FLEXIBLE CONNECTION TO A FIXED GAS S...

Page 6: ...underside of the horizontal surface is in line with the outer edge of the hob If the underside of the horizontal surface is lower than 400 mm then it must be at least mm away from the outer edges of...

Page 7: ...I E E regulations Ventilation requirements The room containing the hob should have an air supply in accordance with the current edition of AS NZS 5601 1 The room must have opening windows or equivalen...

Page 8: ...imum length 1 2m The gas connection has a Rp 1 2 conical thread Any hose assembly used must be restrained from accidental contact with the ue outlet of an under bench oven This hose assembly shall be...

Page 9: ...ickly from the highest to the lowest setting On the highest setting the flame must have a distinctive and visible core If any problem occurs refer to the common faults and solutions Normal Combustionw...

Page 10: ...TO REPAIR THE APPLIANCE YOURSELF The appliance must be accessible for the engineer to perform any necessary repair If your appliance is installed in such a way that an engineer is concerned that damag...

Page 11: ...lit If after 15s the burner has not lit stop operating the device and open the compartment door and wait at least 1 min before attempting a further ignition of the burner After this 15 second interval...

Page 12: ...nds and wipe the steel surfaces of this appliance Cleaning the hob burners The hob burners should be cleaned once a week or more frequently if they get soiled Remove the hob burners by pulling them up...

Page 13: ...e cooper core cooper cap and their seats regularlyfor any displacement or deviation and carry out recti cation accordingly to put them in place so as to avoid the occurrence of accident The gure is pr...

Page 14: ...tion hold and press the switch knob for3 5 seconds to the maximum extend and then release it Causes The cooper core and cooper cap are not in place The knob is not pressed to the maximum extend Bendin...

Page 15: ...iagram Note The supply connection point shall be accessible with the appliance installed 13 JZY B110 JZT B110 JZY G311 JZT G311 JZY B310 JZT B310 JZY G411 JZT G411 JZY B410 JZT B410 JZY G511 JZT G511...

Page 16: ...valve to minimum On gas valves provided with adjustment screw in the center of the shift fig 5 6 Using a screwdriver with max diameter 3 mm turn the screw inside the tap until the correct setting is...

Page 17: ...personnel Customer Support ROBAM 76226 13000 Wechat ROBAM AU _ Facebook www facebook com robamau Youtube www youtube com c robamau Please quote the model and serial number of your appliance when cont...

Page 18: ...Address No 592 Linping Av Yuhang Economic Development Zone Yuhang District 311100 HangzhouCity Zhejiang Province P R China Edition A 0 Publication Date June 02 2018...

Reviews: