Remove the gratings, the burner covers and the knobs;
Using a wrench substitute the nozzle injectors “ "(fig:5.4-5.5)
J
With those most suitable for the kind of gas for which it is to
Be used.
The burner are conceived in such a way so as not to require the
regulation of the primary air.
When switching from one type of gas to another. The minimum
Flow rate needs also be correct: the flame should not go out even
When passing suddenly from maximum to minimum flame.
To regulate the flame follow the instructions below:
Light the burner
Set the gas valve to minimum
On gas valves provided with adjustment screw in the center of the shift
(fig. 5.6).Using a screwdriver with max, diameter 3 mm. turn the screw
inside the tap until the correct setting is obtained.
For LP/PROPANE gas, tighten the adjustment screw completely.
14
Gas Hob
SUBSTITUTING THE INJECTORS
REGULATING THE BURNER
MINIMUM SETTING
TOOL NEEDED
A、T-handle wrench
B、wrench
C、screwdriver
fig 5 6
. .
Examples of a qualified person include licensed heating personnel,
authorized gas company personnel,and authorized service personnel.
Failure to do so can result in death,explosion, or fire.
Manifold pressure should be checked with a manometer. NATURAL gas
requires 1 0kPa. and U L P GAS requires .
kPa. (see page 7).
2 75
fig 5 4
. .
fig 5 5
. .
J
J