SLIDEOUT TROUBLESHOOTING
Doc No:
21906550
Rev: 00
Copyright © Roadtrek Motorhomes Inc. 2009
I - 7
ROOM STARTS TO MOVE AND STOPS
Low battery voltage, blown fuse, defective wiring
Check battery voltage and charge if needed
Find and check fuse, replace if blown
Check battery terminals and wiring
Look for loose, disconnected, or corroded connectors
Obstruction of room inside or outside
Check for and remove any obstruction
Dirt or corrosion buildup on mechanism
Clean dirt or corrosion and coat LIGHTLY with oil
ROOM CHATTERS DURING OPERATION
Teeth on gear drive broken or worn
Replace gear drive assembly
Teeth on inner rail broken or worn
Replace inner rail assembly
Before attempting to troubleshoot the Power Unit (motor), make sure an adequate power source is available. The
unit batteries should be fully charged or the unit should be plugged in to A/C service with batteries installed. Do
not attempt to troubleshoot the Power Unit without assuring a full 12V DC charge.
NOTE: The motor has no field serviceable parts, and so if the motor fails the only repair is to replace the motor.