Specifications
................................................................................................................................................................................................
................................................................................................................................................................................................
Manual TRZ 04 · EN04 · February, 1st 2017
54
To get the Q
min, HP
value for other gas types you can calculate it using the formula in
chapter 1.8.1 Extension of the measuring range or you can contact RMG.
5.4 Values for 2
nd
metering or meters without MID
approval
G
Q
max
m³/h
Q
min
,
LP1)
m³/h
Q
min,HP – natural gas
m³/h
Operating pressure in bar
a
5
10
15
20
30
40
50
60
100
65
100
10
2)
5
4
3
3
2
2
2
2
1
100
160
16
2)
7
6
4
4
3
3
2
2
2
160
250
13
7
6
4
4
3
3
2
2
2
250
400
20
11
8
6
6
5
4
4
3
2
400
650
32
18
13
10
9
7
6
6
5
4
650
1000
50
28
20
16
14
11
10
9
8
6
1000
1600
80
44
31
26
22
18
16
14
13
10
1600
2500
130
72
51
42
36
29
26
23
21
16
1)
LP standard measuring ranges 1:20 and 1:30 (on request)
2)
Measuring range 1:10
It depends on national laws whether these measuring ranges are applicable for custody
transfer metering.