Installation and Commissioning
................................................................................................................................................................................................
................................................................................................................................................................................................
Manual TRZ 04 · EN04 · February, 1st 2017
22
The values for Zp are approximate mean values.
The exact value is calculated from the
pressure loss, which is determined during testing the turbine meter.
Example of calculation
of the pressure loss for a turbine meter with upstream perforated-
plate straightener:
TRZ 04, size DN 150
Qm = 650 m3/h
= 1.3 kg/m3 (natural gas)
From the table on the previous page you may find:
Zp(TRZ04) = 3000
Zp(LP-35) = 1260
Calculation:
Zp(ges) = 3000 + 1260
= 4260
4
2
150
650
3
.
1
4260
p
= 4.2 mbar
1.12 Pressure tap
A pressure tap has been provided to connect the pressure transducer of a volume
corrector or a pressure gauge to read the pressure at measurement conditions prevailing
inside the gas meter. This pressure tap is identified by “p
m
”.
Introduction