Maintenance
Operating Instructions for the TERZ 94 Electronic Turbine Meter
39
Maintenance
Lubrication
The TERZ 94 is fitted with permanently lubricated bearings up to and
including the nominal diameter of DN 150. From the nominal diameter of
DN 200, the meter is fitted with a lubricator. The type of lubricator and the
lubrication instructions depend on the nominal diameter and the pressure
rating:
Nominal dia. Pressure rating Lubricator
Lubrication
instructions
DN 200
PN 10 to 16,
ANSI 150
Oil gun
(supplied)
Every 3 months
2 strokes
DN 200
DN 250
PN 25 to 100
ANSI 300 to 600
PN 10 to 16
ANSI 150
Small oil pump
(pushbutton-
operated)
Every 3 months
6 strokes
DN 250
from DN 300
PN 25 to 100
ANSI 300 to 600
all pressure
classes
Large oil pump
(lever-operated)
Every 3 months
2 strokes
Please observe also the instruction plate on the case.
In the case of unfavourable operating conditions, such as the formation of
water or hydrocarbon condensate or the use of dust-laden gas, we would
recommend performing lubrication at shorter intervals, even daily under
extreme conditions (permanent formation of condensate).
Recommendations for lubricating oils:
Aero Shell Fluid 12 or another oil with 2 to 4°E at 25°C as per MIL-L-6085 A
specification.
Summary of Contents for TERZ 94
Page 2: ......
Page 11: ...Safety Instructions Operating Instructions for the TERZ 94 Electronic Turbine Meter 9...
Page 21: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 19...
Page 23: ...Installation Operating Instructions for the TERZ 94 Electronic Turbine Meter 21...
Page 35: ...Operation Operating Instructions for the TERZ 94 Electronic Turbine Meter 33 3 Test protocol...
Page 62: ...Annex 60 Operating Instructions for the TERZ 94 Electronic Turbine Meter mode are blanked out...