To configure the device sample rate on the web remote:
1. Locate the
Select sample rate
drop down menu in the
CLOCK
section.
2. Select a sample rate from the drop down menu. The new rate is automatically applied.
11.3.4. Effects of Sample Rate Changes on Existing Routing
The M-32 DA Pro saves one routing table per preset, regardless of sample rate. A change of sample rate
or MADI frame mode can reduce the number of input and output channels available for routing. This
does not alter the routing table. Any existing routing is hidden until another change of sample rate re-
enables the channels.
Example:
A routing is created at 96 kHz with 32 channels, sending the MADI coaxial Input 1-32 to optical MADI
Output 1-32. If the sample rate is now changed to 176.4 kHz and the 56 Ch frame is activated, only the
first 14 channels of MADI coaxial input are routed to the optical output. Switching the sample rate to 44.1
or 48 kHz will reveal the previous routing for 32 channels.
11.4. Set Word Clock Output to Single Speed
At sample rates > 48 kHz, it may be necessary to synchronize two devices with a fraction of the actual
sample rate:
Sample Rate
Word Clock Full Speed (default)
Word Clock Single Speed (option)
88.2 kHz
88.2 kHz
44.1 kHz
96 kHz
96 kHz
48 kHz
176.4 kHz
176.4 kHz
44.1 kHz
192 kHz
192 kHz
48 kHz
To set the Word Clock output to single speed on the device:
1. Open the
CLOCK
section.
2. Move the cursor onto the toggle switch
Word Out Single
and push the encoder to change the value.
To set the Word Clock output to single speed on the web remote:
1. Locate the
CLOCK
section.
2. Move the cursor onto the
Word Out Single
switch and push the encoder to change the value.
RME M-32 DA Pro User’s Guide
11.4. Set Word Clock Output to Single Speed |