To change the metering mode on the web remote:
1. Connect to the device remotely (
see:
Section 8.5.1, “Finding the Device on a Network”).
2. Locate the
visual feedback
tab in the
STATE
section.
3. Push the
Peak
or
RMS
button in the
global metering
settings.
This is a global setting which affects both the front panel level meters and the remote
control interface.
8.4.3. Persistent Clipping Notifications and Peak Hold
The maximum level of signals can be saved and shown on the front panel and web remote. Clipping is
detected when three consecutive samples reach digital full scale (0 dBFS). The duration of how long the
maximum level or clipping is shown can be manually changed to either five seconds or until they are
manually reset.
This is a global setting which affects both the remote control and the device. The M-32 DA
Pro does not show peak levels except for clipping events on the device. Peak levels can be
inspected using the web remote.
On the device, an over notification is signaled as a fast flashing (red) of the
label backlight.
To switch over notifications on or off:
1. Open the
visual feedback
tab in the
STATE
section
+ image::p32-140-4T-2.png["Visual Feedback Tab in State section",pdfwidth='40.6mm',align='left']
2. Change
OVR Hold
to either:
◦
5s
to notify for five seconds
◦
On
to notify until manually reset
◦
Off
to deactivate over notifications.
To reset infinite full scale notifications:
1. Open the
visual feedback
tab in the
STATE
section.
2. Activate
Reset
.
RME M-32 DA Pro User’s Guide
8.4. Front Panel Illumination |