Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
282
<Communication identifier list>
Address Identifier
Description
Address Identifier
Description
00
VR
ROM version (Z-COM module)
21
VT
PLC scanning time
01
VR
ROM version (Z-COM module)
22
R5
PLC communication start time
02
VQ
ROM version (Function module)
23
RY
Method for setting the number of con-
nected modules
03
VQ
ROM version (Function module)
24
RK
Slave mapping method
04
UT
Integrated operating time monitor (Z-
COM module)
25
QY
Number of connected modules (Z-TIO
module)
05
UV
Integrated operating time monitor
(Function module)
26
QU
Number of connected modules (Z-DIO
module)
06
ER
Error code (Z-COM module)
27
QO
Number of connected modules (Z-CT
module)
07
EZ
Error code (Function module)
28
QA
Number of valid groups
08
EM
Backup memory state monitor (Z-COM
module)
29
X2
Control RUN/STOP holding setting
(Each unit)
09
CZ
Backup memory state monitor (Function
module)
2A
M1
Measured value (PV)
0A
QM
System communication state
2B
AJ
Comprehensive event state
0B
QL
SRZ normal communication flag
2C
L0
Operation mode state monitor
0C
ES
PLC communication error code
2D
O1
Manipulated output value (MV) monitor
[heat-side]
0D
QN
Unit recognition flag
2E
O2
Manipulated output value (MV) monitor
[cool-side]
0E
QK
Monitor for the number of connected
modules
2F
M3
Current transformer (CT) input value
monitor
0F
SR
RUN/STOP transfer (Each unit)
30
MS
Set value (SV) monitor
10
SW
RUN/STOP transfer (Each module)
31
S2
Remote setting (RS) input value monitor
11
X1
Control RUN/STOP holding setting (Each
module)
32
B1
Burnout state monitor
12
VK
Communication 1 protocol
33
AA
Event 1 state monitor
13
VL
Communication 1 communication speed
34
AB
Event 2 state monitor
14
VM
Communication 1 data bit configuration
35
AC
Event 3 state monitor
15
VN
Communication 1 interval time
36
AD
Event 4 state monitor
16
VP
Communication 2 protocol
37
AE
Heat break alarm (HBA) state monitor
17
VU
Communication 2 communication speed
38
Q1
Output state monitor
18
VW
Communication 2 data bit configuration
39
TR
Memory area soak time monitor
19
VX
Communication 2 interval time
3A
Hp
Holding peak value ambient temperature
monitor
1A
QV
Station number
3B
ED
Logic output monitor 1
1B
QW
PC number (CPU No.)
3C
EE
Logic output monitor 2
1C
QZ
Register type
3D
G1
PID/AT transfer
1D
QS
Register start number (High-order 4-bit)
3E
J1
Auto/Manual transfer
1E
QX
Register start number (Low-order 16-bit)
3F
C1
Remote/Local transfer
1F
System data address bias
40
ZA
Memory area transfer
20
QT
COM module link recognition time
41
AR
Interlock release