Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
274
<Communication identifier list>
Address Identifier
Description
Address Identifier
Description
00
VR
ROM version
32
A7
Heater break alarm (HBA) set value
01
VR
ROM version
33
NE
Heater break determination point
02
M1
Measured value (PV)
34
NF
Heater melting determination point
03
AJ
Comprehensive event state
35
PB
PV bias
04
L0
Operation mode state monitor
36
F1
PV digital filter
05
ER
Error code
37
PR
PV ratio
06
O1
Manipulated output value (MV) monitor [heat-side]
38
DP
PV low input cut-off
07
O2
Manipulated output value (MV) monitor [cool-side]
39
RB
RS bias
08
M3
Current transformer (CT) input value monitor
3A
F2
RS digital filter
09
MS
Set value (SV) monitor
3B
RR
RS ratio
0A
S2
Remote setting (RS) input value monitor
3C
DV
Output distribution selection
0B
B1
Burnout state monitor
3D
DW
Output distribution bias
0C
AA
Event 1 state monitor
3E
DQ
Output distribution ratio
0D
AB
Event 2 state monitor
3F
T0
Proportional cycle time
0E
AC
Event 3 state monitor
40
VI
Minimum ON/OFF time of proportioning cycle
0F
AD
Event 4 state monitor
41
ON
Manual manipulated output value
10
AE
Heater break alarm (HBA) state monitor
42
RV
Area soak time stop function
11
Q1
Output state monitor
43
NG
EDS mode (for disturbance 1)
12
TR
Memory area soak time monitor
44
NX
EDS mode 2 (for disturbance 2)
13
UT
Integrated operating time monitor
45
NI
EDS value 1 (for disturbance 1)
14
Hp
Holding peak value ambient temperature monitor
46
NJ
EDS value 1 (for disturbance 2)
15
EM
Backup memory state monitor
47
NK
EDS value 2 (for disturbance 1)
16
ED
Logic output monitor 1
48
NM
EDS value 2 (for disturbance 2)
17
EE
Logic output monitor 2
49
NN
EDS transfer time (for disturbance 1)
18
G1
PID/AT transfer
4A
NO
EDS transfer time (for disturbance 2)
19
J1
Auto/Manual transfer
4B
NQ
EDS action time (for disturbance 1)
1A
C1
Remote/Local transfer
4C
NL
EDS action time (for disturbance 2)
1B
SR
RUN/STOP transfer
4D
NR
EDS action wait time (for disturbance 1)
1C
ZA
Memory area transfer
4E
NY
EDS action wait time (for disturbance 2)
1D
AR
Interlock release
4F
NT
EDS value learning times
1E
A1
Event 1 set value (EV1)
50
NU
EDS start signal
1F
A2
Event 2 set value (EV2)
51
EI
Operation mode
20
A3
Event 3 set value (EV3)
52
ST
Startup tuning (ST)
21
A4
Event 4 set value (EV4)
53
Y8
Automatic temperature rise learning
22
A5
Control loop break alarm (LBA) time
54
EF
Communication switch for logic
23
N1
LBA deadband
55
XI
Input type
24
S1
Set value (SV)
56
PU
Display unit
25
P1
Proportional band [heat-side]
57
XU
Decimal point position
26
I1
Integral time [heat-side]
58
XV
Input scale high
27
D1
Derivative time [heat-side]
59
XW
Input scale low
28
CA
Control response parameter
5A
AV
Input error determination point (high)
29
P2
Proportional band [cool-side]
5B
AW
Input error determination point (low)
2A
I2
Integral time [cool-side]
5C
BS
Burnout direction
2B
D2
Derivative time [cool-side]
5D
XH
Square root extraction
2C
V1
Overlap/Deadband
5E
E0
Output assignment (Logic output selection function)
2D
MR
Manual reset
5F
NA
Energized/De-energized (Logic output selec-
tion function)
2E
HH
Setting change rate limiter (up)
60
XA
Event 1 type
2F
HL
Setting change rate limiter (down)
61
FA
Event 1 channel setting
30
TM
Area soak time
62
WA
Event 1 hold action
31
LP
Link area number
63
LF
Event 1 interlock