Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
245
<Communication identifier list>
Address
Identifier
Description
00
M1
Temperature measured value (PV) [H-TIO-
, H-CIO-A] / Motor speed measured value
[H-SIO-A]
01
AA
Alarm 1 status [H-TIO-
, H-CIO-A, H-SIO-A]
02
AB
Alarm 2 status [H-TIO-
, H-CIO-A, H-SIO-A]
03
B1
Burnout status [H-TIO-
, H-CIO-A, H-SIO-A]
04
O1
Heat-side manipulated output value [H-TIO-
, H-CIO-A]
05
O2
Cool-side manipulated output value [H-TIO-
, H-CIO-A]
06
AC
Heater break alarm status [H-TIO-A/C/D, H-CIO-A]
07
M3
Current transformer input measured value 1 [H-TIO-A/C/D]
08
M4
Current transformer input measured value 2 [H-CT-A]
09
MS
Set value monitor [H-TIO-
, H-CIO-A, H-SIO-A]
0A
HE
Temperature rise completion status [H-TIO-
, H-CIO-A]
0B
ER
Error code [H-PCP-J]
0C
G1
PID/AT transfer [H-TIO-
, H-CIO-A, H-SIO-A]
0D
S1
Temperature set value (SV) [H-TIO-
, H-CIO-A] / Motor speed set value [H-SIO-A]
0E
P1
Heat-side proportional band [H-TIO-
, H-CIO-A, H-SIO-A]
0F
P2
Cool-side proportional band [H-TIO-
, H-CIO-A]
10
I1
Integral time [H-TIO-
, H-CIO-A, H-SIO-A]
11
D1
Derivative time [H-TIO-
, H-CIO-A, H-SIO-A]
12
V1
Overlap/deadband [H-TIO-
, H-CIO-A]
13
CA
Control response parameters [H-TIO-
, H-CIO-A, H-SIO-A]
14
A1
Alarm 1 set value [H-TIO-
, H-CIO-A, H-SIO-A]
15
A2
Alarm 2 set value [H-TIO-
, H-CIO-A, H-SIO-A]
16
A3
Heater break alarm set value 1 [H-TIO-A/C/D]
17
A4
Heater break alarm set value 2 [H-CT-A]
18
EI
Operation mode transfer [H-TIO-
, H-CIO-A, H-SIO-A]
19
T0
Heat-side proportioning cycle time [H-TIO-
, H-CIO-A]
1A
T1
Cool-side proportioning cycle time [H-TIO-
, H-CIO-A]
1B
PB
PV bias [H-TIO-
, H-CIO-A, H-SIO-A]
1C
SR
Control RUN/STOP transfer [H-PCP-J]
1D
IN
Initial setting mode [H-PCP-J]
1E
ZA
Memory area number [H-TIO-
, H-CIO-A, H-SIO-A]
1F
AR
Alarm interlock release [H-TIO-
, H-CIO-A, H-TI-
, H-AI-
]
20
J1
Auto/Manual transfer [H-TIO-
, H-CIO-A]
21
ON
Manual output value [H-TIO-
, H-CIO-A]
22
HD
Temperature rise completion range [H-TIO-
, H-CIO-A]
23
HS
Temperature rise completion trigger [H-TIO-
, H-CIO-A]
24
T3
Temperature rise completion soak time [H-TIO-
, H-CIO-A]
25
M5
AI measured value [H-AI-A/B]
26
AD
AI alarm 1 status [H-AI-A/B]
27
AE
AI alarm 2 status [H-AI-A/B]
28
A5
AI alarm 1 set value [H-AI-A/B]
29
A6
AI alarm 2 set value [H-AI-A/B]
2A
JI
AI zero point correction [H-AI-A/B]
2B
JJ
AI full scale correction [H-AI-A/B]
2C
NJ
AI operation mode transfer [H-AI-A/B]
2D
AP
Control loop break alarm (LBA) status [H-TIO-
, H-CIO-A]
2E
HP
LBA use selection [H-TIO-
, H-CIO-A]
2F
C6
LBA time [H-TIO-
, H-CIO-A]
30
V2
LBA deadband [H-TIO-
, H-CIO-A]
31
M6
AO output value monitor [H-AO-A/B]
32
S6
AO output set value [H-AO-A/B]