Unit Assembly

 

 

1.  Remove the protective plastic coating 

from the cabinetry of the unit. 

 

2. 

Cast Iron End Plates.

  Position front and 

rear cast iron end plates in firebox.  The 
type of fuel (wood or coal) you primarily 
burn will determine how to locate the end 
plates. 

 

The words, “Wood” and “Coal,” are cast 
into the end plate on opposite sides. If 
you are going to burn wood, position end 
plate with the word, “Wood,” facing out, 
not into the firebox.  If you are going to 
primarily burn coal, position end plate  
with the word, “Coal,” facing out.  The 
purpose of proper location is to introduce 
the precise amount of combustion air into 
the firebox to promote the most efficient 
combustion for either fuel. 

 

3. 

Firebrick.

  Position 6 firebricks for Model 

480EK, or 5 firebricks for Model 360EK, 
standing up on end on the left and right 
side. 

 

4. 

Control Box.

  Mount the 3-speed switch 

control box on lower left side of furnace.  
Four holes are pre-punched. 

 

5. 

Fan Limit Control.

  Remove the cover of 

the fan limit control by grasping the cover 
at the top and bottom and pull outward.  
(Grasping the cover by its side will make 
removal more difficult.) 

 

Attach the control directly above the 
control box into the pre-punched holes 
using the screws provided. 
 
 
 
 
 
 
 
 

Set Pointers.

  Hold dial securely with  

one hand and move the pointers with the 
other hand. Do not force the pointers  
past any stops on the dial even though  
the dial may be graduated beyond the 
stops. 

 

Limit.

  Move the right hand pointer so  

that its straight edge indicates the 

 
temperature at which the contacts should 
open.  The limit pointer should never be 
set any higher than the setting 
recommended by the furnace 
manufacturer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fan.

  Move the “Fan On” pointer so that 

its straight edge indicates the 
temperature at which the fan contacts 
should close to start the blower. Move 
the “Fan Off” pointer so that its straight 
edge indicates the temperature at which 
the fan contacts should open to stop the 
blower. 

 
6. 

Draft Blower or Tube.

  Mount forced 

draft blower or natural draft tube on 
front lower left side of ash pit door. 

 
7. 

Circulation Blower.

  Mount circulation 

blower on rear of the furnace using the 
four bolts supplied. 

 
8. 

Return Air.

  Determine whether your 

return air will enter on the left or right 
side of the furnace.  Assemble the 
optional filter box and mount on furnace 
(see Assembly Schematic on page 11). 

 

Normal fan limit settings are 

140º ON 

95º OFF 

For adjustment of these settings, 

see drawing. 

9. 

Wiring.

  Your Energy King is all pre- 

wired except for the circulation blower on 
the rear of your furnace. Once the blower 
and filter box are mounted on your 
furnace, simply run conduit through the 
hole on the filter box. Next, wire the four 
lead wires onto the four spade  
connectors in the junction box by  
matching colors of wire and following the 
applicable wiring diagram. 
 

Black 

     High Speed 

Blue 

     Medium Speed 

Red 

     Low Speed 

White 

     Neutral 

 

7

Summary of Contents for ENERGY KING 360EK

Page 1: ...Wood or Coal Furnaces Models 360EK and 480EK Installation Operation Maintenance Manual RJM Manufacturing Inc PO Box 27 1875 Olson Drive Chippewa Falls WI 54729 715 720 1794 Fax 715 720 1797...

Page 2: ...he installation must be performed by a qualified installer With proper installation and maintenance your Furnace will give you years of trouble free service Energy King s Furnace is designed to burn A...

Page 3: ...ng Diagram Forced Draft 9 Wiring Diagram Manual Draft 10 Filter Box Assembly Schematic 11 STOVEPIPE INSTALLATION 12 BAROMETRIC DRAFT INSTALLATION 12 AIR DUCT INSTALLATION 12 OPERATION 13 GENERAL INSTR...

Page 4: ...ill cause safety and operation problems 8 Do not connect your solid fuel appliance to a chimney flue already venting another appliance 9 Do not let an accumulation of either soot or creosote build up...

Page 5: ...022 98 Cast Iron Hearth End Plates 2 EK007 98 Ash Pan removable EK023 98 Shroud Top EK008 98 Self Tapping Bolts 3 EK024 98 Shroud Left Side EK009 98 x Bolts 8 EK025 98 Shroud Right Side EK010 98 Nuts...

Page 6: ...ant step in positioning your wood coal furnace is the distance from your new or existing chimney The unit should be installed as close to the chimney as possible with a minimum of elbows no more than...

Page 7: ...is added A common mistake is to assume that sheet metal masonry or asbestos board placed directly against a wall protects it Materials installed in this manner give very little protection These materi...

Page 8: ...it and the supplemental unit must be compatible If all these conditions are met then the combined static pressure may not exceed that established by the existing furnace Once it has been determined th...

Page 9: ...mn All chimney connections must meet the approval of the local building inspector and fire marshall and conform to all local state and national codes It is also necessary to clean your chimney of creo...

Page 10: ...nters past any stops on the dial even though the dial may be graduated beyond the stops Limit Move the right hand pointer so that its straight edge indicates the temperature at which the contacts shou...

Page 11: ...Wiring Diagram Auto Draft 8...

Page 12: ...9 9...

Page 13: ...Wiring Diagram Manual Draft 10...

Page 14: ...Filter Box Assembly Schematic CAUTION THE FILTER MUST BE REMOVED IF THE FAN IS INOPERABLE FOR ANY REASON THIS WILL PREVENT OVERHEATING OF THE MOTOR THE AIR FILTER MUST BE NON COMBUSTIBLE 11...

Page 15: ...n Dampers in Stovepipes Put a manual damper at a safe convenient place between the chimney and your Energy King furnace In case of a chimney fire it can quickly be closed reducing draft to the chimney...

Page 16: ...weather Your automobile engine works effectively at 55 mph but can be damaged or destroyed at constant speeds of 90 mph Your furnace can be damaged if it is constantly fired at extremely high tempera...

Page 17: ...couple of handfuls of dry thick kindling wood then several small pieces of firewood Be sure the bypass damper is open 3 It will take 5 to 10 minutes for the fire to establish itself Once you have som...

Page 18: ...build up the coal bed 5 Allow your Energy King to operate with drafts on for approximately 15 minutes or until fresh coal ignites When the coal is properly ignited adjust the thermostat accordingly 6...

Page 19: ...ntly creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot hot fire The chimney connector and chimney should be inspected at least twice monthly during the...

Page 20: ...eaks Door gaskets glass gaskets ash drawer or door gaskets where applicable Unit does not give off enough heat Is the unit installed correctly 1 Check to see if the unit has an adequate cold air retur...

Page 21: ...n cause creosote buildup in smoke pipe and chimney Coal fire goes out or does not hold overnight Check for the following conditions 1 Poor draft 2 Incorrect damper settings 3 Improper firing methods f...

Page 22: ...ter preheating the chimney If hardwoods are unavailable you can control your fire s burn rate by using larger pieces of wood Q Is it important to season wood before burning it R The seasoning or dryin...

Page 23: ...hase All transportation charges on warranty appliances and appliance parts submitted for repair or replacement under this warranty shall be paid for the by purchaser field analysis of condition remova...

Reviews: