background image

PRODUCT MANUAL

T

raining

 

and

 T

echnology

 

for

 i

njecTion

 M

olding

L

ynx

™ S

hielded

 S

equence

 M

odule

ID7‑M‑SEQ

Summary of Contents for Lynx ID7-M-SEQ

Page 1: ...PRODUCT MANUAL Training and Technology for Injection Molding Lynx Shielded Sequence Module ID7 M SEQ...

Page 2: ...PRINT DATE 12 16 2019 REVISION NO 0...

Page 3: ...MER III PRIVACY III ALERTS III PRODUCT DESCRIPTION APPLICATIONS 1 PROCESS MONITORING AND CONTROL 1 OPERATION 2 MACHINE SEQUENCE SIGNALS 2 eDART SEQUENCE SIGNALS 4 DIMENSIONS 5 CABLE LENGTHS 5 INSTALLA...

Page 4: ...ESHOOTING COMMON ERRORS 13 SIGNAL ERRORS 13 ACCEPTABLE SIGNAL SUBSTITUTIONS 14 CUSTOMER SUPPORT 15 RELATED PRODUCTS COMPATIBLE PRODUCTS 17 SHIELDED SEQUENCE MODULE CABLE C ID7 M 3M 17 LYNX CABLES CE L...

Page 5: ...d uses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or design...

Page 6: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual iv RJG Inc...

Page 7: ...in order to accurately calculate significant process values for monitoring and control The ID7 M SEQ gathers the machine sequence state signals from the injection molding machine for the eDART The eDA...

Page 8: ...push plastic into the mold and ends when it stops applying pressure when hold begins The eDART uses the injection forward signal as the start of the cycle Without the injection forward signal the eDAR...

Page 9: ...indicates when the mold is opening during a cycle If the signal is on when the mold is opening assign it as mold opening 7 Manual The manual signal is assigned to indicate the machine s current operat...

Page 10: ...RT which uses the transfer pressure set in cavity pressure control If cavity pressure control is not in use pack will only exist if the fill signal is considered to be a fill and pack combined signal...

Page 11: ...Product Manual Lynx Shielded Sequence Module ID7 M SEQ RJG Inc 5 DIMENSIONS CABLE LENGTHS The C ID7 M 3M is 9 8 ft 3 m long CABLE LENGTH...

Page 12: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 6 RJG Inc...

Page 13: ...able C ID7 M 3M is wired directly to the machine usually to an output card on one end and connected to the ID7 M SEQ on the other using the eight pin connector eDART CONNECTION A Lynx cable CE LX5 is...

Page 14: ...the signals are misnamed or do not go on and off as specified the system generated machine sequence signals will likely be incorrect as will the data calculated from them Refer to Machine Sequence Si...

Page 15: ...detects stroke direction zeroes plastic volume at cycle This signal is required Mold Closed Clamped MC Mold Clamped to High Tonnage Mold Begins to Open Primary signal for cycle time calculation zeroin...

Page 16: ...future software setup and use The C ID7 M 3M cable has colored coded wires to simplify installation Refer to the table below for the correct wire signal combinations for installation SIGNAL WIRING COL...

Page 17: ...signals select the Sequence Inputs inputs button on the Sequence Lights tool Similarly the Sequence Inputs tool displays the hard wired signals statuses With the machine in manual mode cycle the machi...

Page 18: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 12 RJG Inc...

Page 19: ...d the eDART sequencer can adjust for some of these abnormalities For example if the screw run signal is available it will reject additional injection forward on signals until after the screw stops Wit...

Page 20: ...Mold clamped plus a set time to turn on and a set injection forward on time detected by eDART 2 No mold closed clamped signal If no mold closed clamped signal is available but both mold opening and m...

Page 21: ...uence Module ID7 M SEQ RJG Inc 15 CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 8170 email CustomerSupportGroup r...

Page 22: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 16 RJG Inc...

Page 23: ...ID7 M 3M provides a connection from molding machines sequence output card and the RJG Inc ID7 M SEQ 1 2 3 LYNX CABLES CE LX5 The Lynx sensor cable 2 at right is a polypropylene coated cable suited fo...

Page 24: ...panels LYNX SHIELDED DUAL RELAY OUTPUT MODULE OR2 M The Lynx shielded dual relay output module OR2 M 2 at right is a shielded DIN rail mounted module that interfaces the eDART and sorting equipment or...

Page 25: ......

Page 26: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Reviews: