Product Manual | Lynx™ Shielded Sequence Module ID7‑M‑SEQ
RJG, Inc.
3
4.
Screw Run
Screw run is the portion of the molding cycle
during which the machine begins to rotate the
screw to build the next shot; it beings when
recovery begins and ends when recovery ends
(the next shot has been built).
5.
Mold Closed/Clamped
The mold closed/clamped signal indicates when
the mold is closed during a cycle. If the signal is
on only when the mold is clamped, assign it as
“mold closed/clamped”. If the signal is on when
the mold is closing, assign it as “mold closing”.
6.
Mold Opening
The mold opening signal indicates when the
mold is opening during a cycle. If the signal is
on when the mold is opening, assign it as “mold
opening”.
7.
Manual
The “manual” signal is assigned to indicate the
machine’s current operational mode—machine
in manual (mode). The signal must be on only
when the machine is in manual mode, and must
turn off when it is in auto or semi‑auto mode.
This enables the operator to verify that the
other sequence signals are correctly wired and
assigned by cycling the different functions while
in manual mode to verify that the corresponding
sequence signal module light is activated.
8.
Shuttle Position
The shuttle position signal (for use with shuttle
molding tables only) indicates to the
eDART
in
which position the table is currently—Shuttle
Position A, B, C, etc.
OPERATION (
continued
)
Summary of Contents for Lynx ID7-M-SEQ
Page 2: ...PRINT DATE 12 16 2019 REVISION NO 0...
Page 6: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual iv RJG Inc...
Page 12: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 6 RJG Inc...
Page 18: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 12 RJG Inc...
Page 22: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 16 RJG Inc...
Page 25: ......