Product Manual | Lynx™ Shielded Sequence Module ID7‑M‑SEQ
RJG, Inc.
11
MAINTENANCE
The shielded sequence module requires little
to no maintenance provided that all installation
instructions are followed.
CLEANING
REGULAR CLEANING
Cables must be installed in areas free from oil,
dirt, grime, and grease.
RJG, Inc. recommends the following cleaners:
•
Microcare MCC‑CCC Contact Cleaner C
•
Microcare MCC‑SPR SuprClean™
•
Miller‑Stephenson MS‑730L Contact Re‑Nu
®
TESTING
Test the ID7‑M‑SEQ inputs after assignment
using the Sequence Lights/Sequence Inputs tool
in
eDART
version 9.xx software, or in Machine
Setup/Test Inputs in
eDART
version 10.xx
software, or utilize the integrated LED on the
ID7‑M‑SEQ to verify that the corresponding
light goes on/off for the machine sequence.
eDART
VERSION 9.XX SOFTWARE
The Sequence Lights tool displays what stage of
the process is taking place showing the on/off
status of machine sequences. If a “light” is on,
then the signal is on; if a “light is off, the signal is
off. The Sequence Lights tool displays machine
sequences that are not necessarily wired to
the sequence module. To view the status of
the hard‑wired sequence signals, select the
Sequence Inputs inputs button on the Sequence
Lights tool.
Similarly, the Sequence Inputs tool displays the
hard‑wired signals statuses. With the machine in
manual mode, cycle the machine while watching
to verify that the corresponding “light” goes on/
off for the machine sequence.
eDART
VERSION 10.XX SOFTWARE
The Machine Setup/Test Inputs function displays
the hard‑wired signal statuses. With the
machine in manual mode, cycle the machine
while watching to verify that the corresponding
“light” goes on/off for the machine sequence.
WARRANTY
RJG, INC. STANDARD WARRANTY
RJG, Inc. is confident in the quality and
robustness of the shielded machine interface
modules, and so are offering a one‑year
warranty. RJG’s products are guaranteed against
defects in material and workmanship for one
year from the original date of purchase. The
warranty is void if it is determined that the
adapter was subjected to abuse or neglect
beyond the normal wear and tear of field
use, or in the event the adapter box has been
opened by the customer.
PRODUCT DISCLAIMER
RJG, Inc. is not responsible for the improper
installation of this equipment, or any other
equipment RJG manufactures.
Proper RJG equipment installation does not
interfere with original equipment safety features
of the machine. Safety mechanisms on all
machines should never be removed.
Summary of Contents for Lynx ID7-M-SEQ
Page 2: ...PRINT DATE 12 16 2019 REVISION NO 0...
Page 6: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual iv RJG Inc...
Page 12: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 6 RJG Inc...
Page 18: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 12 RJG Inc...
Page 22: ...Lynx Shielded Sequence Module ID7 M SEQ Product Manual 16 RJG Inc...
Page 25: ......