4. OPERATING INSTRUCTIONS
ﻞﻴﻐﺸﺘﻟا
تﺎﻤﻴﻠﻌﺗ
4./21
PHASE 4: Reach of welding pressure
Pull the distributor lever with gradual increasing force until you reach the pressure
(P
1
+P
t
)
within the
t
4
time.
= t
4
ﺔﺴﻣﺎﺨﻟا
ﺔﻠﺣﺮﻤﻟا
:
مﺎﺤﻠﻟا
ﻂﻐﻀﻟا
ﺖﺒﺛ
.
=
5
ٍناﻮﺛ
عزﻮﻤﻟا
عارذ
رﺮﺣ
.
ﺖﻗﻮﻟا
ﻲﻬﺘﻨﻳ
ﻰﺘﺣ
ﺮﻈﺘﻧا
t
5
.
ﺖﻗﺆﻤﻟا
2
=
t
5
PHASE 5: Welding
Stabilize the pressure.
= 5 sec
Slowly release the distributor lever.
Wait for the
t
5
time to end.
Timer 2
=t
5