ritm Contact GSM-9? Operating Manual Download Page 25

www.ritm.ru

25 of 93

Operating Manual. Contact GSM-9N

/А/М

Contact GSM-9М

Indicator

State

Value

(blue)

On

At least one of security areas (excl. fire 
protection areas and ‘24 hours’) is armed.

Blinking

Alarm in an area (excl. fire protection areas).

Off

All areas are disarmed (excl. fire 
protection areas and ‘24 hours’).

(blue)

On

The panel is powered from the battery.

Off

The panel is powered from the main power supply (220V).

(blue)

On

Operational power (12V or 220V) available.

(red)

On

All zones in non-armed areas are normal.

Off

At least on zone in non-armed areas is not 
normalized or all areas are armed.

SIM1, SIM2 

(on-board 

indicators)

On

SIM card is active.

Off

The SIM card is not active.

Summary of Contents for Contact GSM-9?

Page 1: ...Saint Petersburg 2017 Control panels Contact GSM 9N Contact GSM 9 Contact GSM 9 Operating Manual Rev 1 0...

Page 2: ...ion 19 Selecting and Installing SIM cards 19 Installation and connection 20 Installation Procedure 20 Indication 22 Contact GSM 9N 22 Contact GSM 9 24 Contact GSM 9 25 Standalone configuration 26 Pane...

Page 3: ...odes 64 Touch Memory keys 68 Output terminals 72 Engineering Numbers 74 SMS messages 76 History 78 Update 81 Service 83 Adding to GEO RITM 85 Maintenance 87 Safety Measures 88 Transportation and Stora...

Page 4: ...and logically dedicated part of a security system Monitoring server A server to which the device transmits data through configured communication channels Tamper A contact located under the device cov...

Page 5: ...are designed for setting up security at remote real estate objects apartments offices country houses and other real estate objects This manual contains data on the design principle of operation prope...

Page 6: ...other objects Messages to the monitoring software are transmitted via GSM network through GPRS CSD SMS channels The panels features are the following Connection up to 3 hardwired zones of dry contact...

Page 7: ...ensor Transmitting messages to the monitoring software or to a user using the Ademco Contact ID protocol specify the names of areas and zones directly in the software settings Event history All events...

Page 8: ...se configuration software 3 Remotely using CSD modem Partial panel setup without using PC1 The Contact GSM 9N panel could be partly setup in standalone mode In this case the setup is performed with a...

Page 9: ...on device connection 2 outputs of the panel can host a number of various actuation devices such as sirens illuminated panels and indicators Hardwired zones The panel allows to connect up to 3 dry cont...

Page 10: ...M antenna 2 With external GSM antenna In this case the device has a connector for the antenna SMA connector on the fig 1 Figure 1 XS1 SA1 TM LED GND 1 2 3 ZONES STAY ZONES EXIT BYPASS CANCEL ARMED INS...

Page 11: ...tatuses of areas assigned to the EXIT button is connected to terminals 1 and U OK A siren is connected to 2 and U OK terminals TM LED GND Terminals for Touch Memory reader connection TM output positiv...

Page 12: ...Ah enclosure The panel is equipped with a built in Touch Memory reader and a visual frame with Armed Battery and Ready indicators Figures 2 3 and 4 show panel circuit board design and dimensions of en...

Page 13: ...www ritm ru 13 of 93 Operating Manual Contact GSM 9N Figure 3 ARMED BATTERY READY Contact 1 2Ah enclosure Figure 4 ARMED BATTERY READY Contact 7Ah enclosure...

Page 14: ...d acid battery connector The GND terminal is negative and the BAT terminal is positive for the battery TM LED GND Terminals for Touch Memory reader connection TM output positive terminal for connectin...

Page 15: ...made in plastic enclosure and has 2 versions 1 Contact GSM 9M TM control panel is equipped with a Touch Memory key reader built in the enclosure 2 Contact GSM 9M TM control panel is equipped with a RF...

Page 16: ...www ritm ru 16 of 93 Operating Manual Contact GSM 9N Figure 6 Contact GSM 9...

Page 17: ...n the enclosure optionally depending on the version 8 Spring contacts Spring contacts are connected to the indication board on the top cover of the enclosure 9 Battery location Backup battery compartm...

Page 18: ...ct GSM 9 version Max number of TM keys pcs 16 Number of events in history 65 535 Configuring parameters using PC Yes GSM signal strength indication using keypad for Contact GSM 9N version Number of ba...

Page 19: ...el 2 The GPRS session opening is not charged 3 The traffic is charged at the end of the day session 4 The rounding threshold for the traffic charging is the lowest Selecting and Installing SIM cards T...

Page 20: ...lines Heaters and ventilation systems Protect the panel from moisture 1 Open the panel enclosure 2 Run all wires through an opening in the enclosure back cover 3 Securely fasten the back enclosure cov...

Page 21: ...ply to the power terminals 12 GND of Contact GSM 9N circuit board i If the contact GSM 9N panel is connected to a Ritm power supply connect the wire from the CPW terminal of power supply to the CPW te...

Page 22: ...med areas is not normalized or all areas are armed FIRE3 On Risk of fire one fire detector triggered Blinking Fire alarm two or more fire detectors triggered Off Fire areas are normal INSTANT On Devic...

Page 23: ...ZONES 1 16 The Zones button is pressed States of zones 1 6 are shown Off Zone is OK On Zone with fire alarm3 is possible in zone Blinks slowly Zone in fire3 alarm Blinks rapidly Zone failure The Zone...

Page 24: ...re protection areas and 24 hours BATTERY On The panel is powered from the battery Off The panel is powered from the main power supply 220V READY On All zones in non armed areas are normal Off At least...

Page 25: ...Off All areas are disarmed excl fire protection areas and 24 hours blue On The panel is powered from the battery Off The panel is powered from the main power supply 220V blue On Operational power 12V...

Page 26: ...2 Upon entering a command device indicators 1 5 lights up Indication designation is the following the indicator 1 is on the signal strength is 20 the indicators 1 and 2 are on the signal strength is 4...

Page 27: ...e 0 under no duress 1 under duress A numbers of arming areas from 1 to 6 For example 1234 4 1 22220 123456 In this example a new value of 2222 for arming areas 1 2 3 4 5 and 6 with no duress is assign...

Page 28: ...onnect to the panel you can use remote GSM CSD connection or a USB2 PC connection cable CSD connection i To establish a CSD connection use a GSM modem connected to the PC Before using the multiuse con...

Page 29: ...www ritm ru 29 of 93 Operating Manual Contact GSM 9N Figure 7 Configuring the CSD connection in the ritm conf software Figure 8 Configuring the CSD connection in the Ritm Configure...

Page 30: ...n program GSM modem_Ritm Drivers zip To connect to the panel please specify the following settings in the configuration software properties Connection type USB COM cable COM port COM port number to wh...

Page 31: ...SB connection in the Ritm Configure software i Use the Device Manager to identify the port number used by the operating system In the Ports section find the port name Silicon Labs CP210xUSB to UART Br...

Page 32: ...www ritm ru 32 of 93 Operating Manual Contact GSM 9N Figure 11 Driver Check...

Page 33: ...card tab Equipment Fig 12 Under the panel image click Device Setup Figure 12 Configuring the panel using GEO RITM Configuration using Ritm Link To access the configuration software via RITM Link cloud...

Page 34: ...ll specified settings are reset Figure 14 The Save changes button The configuration software window is separated into the following areas Fig 15 1 Configuration software sections 2 Settings section 3...

Page 35: ...Operating Manual Contact GSM 9N Figure 15 Configuration software window...

Page 36: ...unauthorized access to panel configuration Default value 1234 GSM signal level SIM 1 2 Shows the current level of GSM signal To connect to the network and update GSM signal level details click the Tes...

Page 37: ...Operating Manual Contact GSM 9N Figure 16 Global Settings section...

Page 38: ...ecting the panel s operability are generated i System events are recorded with 0 as the zonenumber and 0 as the area number Generate a daily autotest i An automatic test is a special event generated b...

Page 39: ...is off and a backup power supply voltage drops down to 11V i Note in 3 hours after power supply the 302 3 Rcv Battery discharge is generated Generate the events 220V failure recovery Set the period ov...

Page 40: ...dentify which mode is used for panel configuration the zone encodes the following details 0 configuration via cable 99 configuration over CSD channel using the phone number not marked as an Engineerin...

Page 41: ...Operating Manual Contact GSM 9N Figure 17 System Events section...

Page 42: ...ses a predefined set of providers To view them click Additionally When disabling the Specify APN configuration automatically please specify GPRS phone number GPRS activation number normally 99 Access...

Page 43: ...tion min Set the value of the pause between connection attempts via Online channel During this pause the data may be transferred via Offline communication channels see section Communication channels a...

Page 44: ...Operating Manual Contact GSM 9N Figure 18 GPRS parameters section...

Page 45: ...ipient in case one of the channels is failed Communication channels are combined to form the direction using the OR switch and the directions are separated using the AND switch i It is a common practi...

Page 46: ...monitoring software Check connection with server in GPRS Online channel in Upon operation through a GPRS TCP IP communication channel via SIM1 SIM2 specify a rate for sending PING command to the monit...

Page 47: ...monitoring software server only to transfer the events and disconnects after the events have been transferred ContactID via digital channel GSM V 32 110 SIM1 SIM2 Intented to transfer events to a Con...

Page 48: ...Operating Manual Contact GSM 9N Figure 19 Communication channels section...

Page 49: ...one another but only one hardwired zone type can be used at a time The used hardwired zone type is defined in this section using the Resistive Dry contacts switches Troubleshooting code Regardless of...

Page 50: ...fire hardwired zones 5 Entrance delay sec If the hardwired zone is used to connect entry area sensors indicate the time in seconds which the user will have to disarm the area without activating the al...

Page 51: ...Operating Manual Contact GSM 9N Figure 20 Hardwired zones properties section...

Page 52: ...p properties of existing areas A unique area number from 1 to 6 The area number allows to identify the room in which the alarm has been tripped Area state This field shows the current state of the sys...

Page 53: ...o connect fire sensors set the fire areas Fire areas are instant Hardwired zones processing logic also changes if two hardwired zones are in a violated state an event 110 1 Alarm Fire is generated If...

Page 54: ...the counter resets If there are no need to limit the number of generated events set the value to No limitations Arming without connection to the server Allow arming if no connection to the server The...

Page 55: ...Operating Manual Contact GSM 9N Figure 21 Areas Configuration section...

Page 56: ...n the hardwired zones To configure the resistance of the hardwired zones for every type of sensors individually To use fire sensors7 If the resistors from the delivery package are used for connection...

Page 57: ...e position of the lower indicators located under the resistance scale for the hardwired zone The color of each indicator corresponds to a part of the hardwired zone on the resistance scale which it af...

Page 58: ...larm Zone 1 Alarm Zone 2 Alarm Zone 1 2 Short circuit Configure the operating thresholds trigger each sensor one by one the first the second both sensors the breakage and its short circuit and use the...

Page 59: ...Operating Manual Contact GSM 9N Figure 24 Hardwired zones settings resistive hardwired zones...

Page 60: ...an enable only one security sensor i Please note For dry contact hardwired zones the operating thresholds are not configured When using the dry contact hardwired zone the areas can not be fire see sec...

Page 61: ...Operating Manual Contact GSM 9N Figure 25 Hardwired zones settings dry contacts...

Page 62: ...rm certain outdoor areas using the Perimeter button without entering the user code indicate them from the drop down list Normally arming using the Perimeter button is used when a user wants to stay in...

Page 63: ...Operating Manual Contact GSM 9N Figure 26 Keypads section...

Page 64: ...er address or combinations like 0000 or 1234 Do not tell your combinations to third parties Keep the code in a secure place or remember it which is better Adding a new user code To add the code click...

Page 65: ...re armed after entering of the user code including the duresse code an event 402 3 Arming the area is generated When the areas are disarmed except using the duresse code the 402 1 Disarming the area e...

Page 66: ...ser code D A where Code numder a code index digit from 0 to 9 0 refers to 10 D duresse 0 under no duress 1 under duress A numbers of arming areas from 1 to 6 For example 1234 4 1 22220 123456 To inter...

Page 67: ...Operating Manual Contact GSM 9N Figure 27 Keypad codes section...

Page 68: ...equency of 1 time per second alarm in the area Adding a new key To add a new TM key to the system click Add type 16 digit key number or touch the key to the TM reader and click Read the key Additional...

Page 69: ...ed by its one time application i Note that if you connect at least one smart reader to the panel all other connected readers start working according to the logic of smart one they will support the dou...

Page 70: ...armed Blinking Alarm in any area incl fire protection areas and 24 Off At least one of security areas is not armed i The alternating flashing of yellow and red indicators no more than 5 seconds means...

Page 71: ...Operating Manual Contact GSM 9N Figure 28 Touch Memory Keys section...

Page 72: ...ypads For Contact GSM 9A M duplicates the condition of the selected areas parameter Indication of area status OK2 output OK1 output is designed to connect the siren Operation mode of the siren is conf...

Page 73: ...Operating Manual Contact GSM 9N Figure 29 Outputs section...

Page 74: ...hone number To enable configuring of the panel from specific engineering phone numbers only fill in the blank fields in this section in the format used by the communications provider For example and c...

Page 75: ...Operating Manual Contact GSM 9N Figure 30 Engineering Numbers section...

Page 76: ...ipher therefore it should be brought into the form Disarming area 1 using the key 2 The manufacturer settings allow using SMS for the user without additional setup If an event needs to be clarified pi...

Page 77: ...Operating Manual Contact GSM 9N Figure 31 SMS messages section...

Page 78: ...recovery Event shows the description of an event Area is the number of the area in which the event has been generated Hardwured zone or TM is the number of a hardwired zone user code key involved in...

Page 79: ...xt format To do that specify the number of entries and read them clicking the Read the records link After that click the link Export of the read history to txt Deleting history To delete the history f...

Page 80: ...Operating Manual Contact GSM 9N Figure 32 History section...

Page 81: ...date version download and install all previous versions To update the panel software follow the following steps 1 Select a firmware version to update 2 Click Start updating to begin downloading the so...

Page 82: ...Operating Manual Contact GSM 9N Figure 33 Updates Section...

Page 83: ...k the Read settings from the device link and wait for the loading to finish After this click the Save settings into the file link and specify where you wish to save the file Use the settings file to a...

Page 84: ...Operating Manual Contact GSM 9N Figure 34 Service Section...

Page 85: ...e wizard hints during the registration procedure In case of questions please refer to GEO RITM document User Manual Log into your account In the main menu select the Stationary Objects section Click A...

Page 86: ...Operating Manual Contact GSM 9N Figure 36 GEO RITM Service...

Page 87: ...ing Manual Contact GSM 9N Maintenance At least once per month check SIM card accounts for funds At least twice per year visually inspect the panel for enclosure or connector damages Clean the terminal...

Page 88: ...www ritm ru 88 of 93 Operating Manual Contact GSM 9N Safety Measures All setup and maintenance activities applied to the panel should be performed by duly qualified personnel...

Page 89: ...ckaging in closed vehicles Storage conditions should conform to those listed in 1K1 under EN 60721 3 1 Transportation conditions should conform to those listed in 1K1 under EN 60721 3 2 Storage premis...

Page 90: ...tion Although the warranty exploitation period is 12 months from the commissioning date it may not exceed 18 months from the production date The warranty storage period is 6 months from the production...

Page 91: ...ting Manual Contact GSM 9N Contact Details Main office Moscow office Saint Petersburg Russia 195248 Moscow Russia 127051 pr Energetikov 30 bld 8 2 Kolobovskiy per 13 14 7 812 325 01 02 7 495 609 03 32...

Page 92: ...us metals dangerous or toxic substances possible to harm to health or environment and does not pose a hazard to life health or environment after expiration of term of service Therefore panel disposal...

Page 93: ...www ritm ru 93 of 93 Operating Manual Contact GSM 9N Change history Revision Revision date Description 1 0 25 04 2017 Full revision of document...

Reviews: