16
PUB. NO. FASTRAXC FEBRUARY 2008
FASTRAX
™
PHOTOEYES CABLES / INSTALLATION
1.
Cut wire ties holding photoeye cables.
2.
Route non-drive photoeye cable across the top of the
opening using the cable clamps provided,
Figure 30.
3.
Plug drive, non-drive photoeye cables and control box
conduit cable into the electrical module,
Figure 23.
DRIVE TUBE PHASING
1.
With control box installed, turn disconnect to "ON".
2.
When pressing the "OPEN" button, the drive tube should
rotate counter-clockwise on right hand drive door and
clockwise on left hand drive door. (The back of the tube
should be turning toward the ceiling.)
3.
If the drive tube rotates in the opposite direction, switch
wires in motor terminals U & V.
4.
If motor rocks excessively, tighten bumpers.
CURTAIN INSTALLATION
(Determine phase first)
1.
Remove the two 3/8” hex head bolts holding the front
curtain retainers in place (both sides),
Figure 24.
2.
Place curtain in front of the opening.
3.
On FasTrax FR it is required and on FasTrax model, it
may be required to remove both top curtain rollers to feed
through drive gears (two-7/16” bolts),
Figure 25.
4.
Disengage brake by tightening the handle on the brake.
5.
Position curtain so that the top edge with the metal
stiffener is facing toward the wall,
Figure 25.
6.
Using a lift, raise curtain and feed top drive sphere around
the back side of the drive gear and into the radius and/or
track,
Figure 26.
7.
Rotate drive tube to drive curtain through the drive gears.
8.
Loosen brake release handle and secure to clip.
9.
Fasten top curtain roller bracket back onto the top curtain
brace (FasTrax FR), if removed earlier (FasTrax). Note,
FR door will also need to have exhaust cup attached to
the curtain roller bracket,
Figure 27.
10.
Install front curtain retainers back onto the lower track,
Figure 24.
NOTE: Make sure front curtain guides are flush with lower
track when installing.
11.
Fasten hose from curtain to exhaust cup on roller bracket
Figure 27.
12.
For FasTrax FR only - Install hose between E-Vac blower
and lower track E-Vac cup,
Figure 28.
CURTAIN INSTALLATION
FIGURE 25 - TOP CURTAIN ROLLERS
*Top Curtain
Roller Bracket
FIGURE 24 - CURTAIN GUIDE
Mount Guide Flush
With Inside of Track
FIGURE 23 - MODULE
P.E. Cut-off & Closed
Limit Switch Plug
Non-Drive
P.E. Plug
I-Zone
Plugs
Control Box
Cable Plug
Open Limit
Switch Plug
Drive P.E. Plug
Photoeye
LED’s
Photoeye
Relays
*Top curtain roller bracket should be positioned such that the
roller shaft is toward the curtain and away from the wall.
I M P O R T A N T ! ! !
Curtain drive spheres MUST be fed level into the drive gears with
the same amount of spheres above the drive tube, or curtain will
not be level.
I M P O R T A N T ! ! !
Top-54"
Bottom-18"
Special
Front Curtain Retainer
DO NOT Overtighten
Fasteners
Back Wall
Side
Lifting Handle
Summary of Contents for FASTRAX
Page 13: ...PUB NO FASTRAXC FEBRUARY 2008 13 FASTRAX i COMM LOGIC CHART FIGURE 22 LOGIC CHART...
Page 32: ...32 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX VIRTUAL VISION ELECTRICAL WIRING...
Page 36: ...36 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX RADIAL ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 37: ...PUB NO FASTRAXC FEBRUARY 2008 37 FASTRAX VERTICAL ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 38: ...38 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX STANDARD LIFT ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 39: ...PUB NO FASTRAXC FEBRUARY 2008 39 FASTRAX HIGH LIFT ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 40: ...40 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX 45 TILT ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 41: ...PUB NO FASTRAXC FEBRUARY 2008 41 FASTRAX FR VERTICAL ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 42: ...42 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX FR STANDARD ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 43: ...PUB NO FASTRAXC FEBRUARY 2008 43 FASTRAX FR HIGH LIFT ARCHITECTURAL DRAWING D O O R SYSTEM...
Page 44: ...44 PUB NO FASTRAXC FEBRUARY 2008 FASTRAX FR 45 TILT ARCHITECTURAL DRAWING D O O R SYSTEM...