User Functions and Settings
Page
31
Authority Levels
Level
Description
GRAND
MASTER
All operations for all partitions. There is only one grand master
code in the system, and it is designated as user index number
00
.
This code can be changed by the engineer or the grand master.
Notes:
Your LightSYS2 was given a grand master code of 1-2-3-4 during
manufacturing. RISCO advises that you modify this code to one
that is unique and personalized as herein described, unless your
alarm company has already done so.
MASTER
All operations but only for designated partitions. The user holding
the master code can change the master code and the codes of all
authority levels lower than master. LightSYS2 supports an
unlimited numbers of master codes.
USER
Only basic operations for one or more partitions.
DURESS
Like USER except that when unsetting the system a duress alarm
message is sent to the alarm receiving centre.
SET ONLY
Setting one or more partitions.
Set only codes are useful for
workers who arrive when the premises are already open but,
because they are the last to leave, are given the responsibility to
close and secure the premises at the day’s close.
CLEANER
Used only for one-time setting and unsetting, after which the code
is automatically erased and should be redefined. This code is
typically used residentially for maids, home attendants, and
repairmen who must enter the premises before the owner(s) arrive.
UNOMIT
Basic operations to one or more partitions without the ability to
omit zones.
GUARD
Typically used to enable a guard to unset the system for a
predefined amount of time. After this period, the system is
automatically set again.
PO ONLY
Typically used to enable the operation of a device controlled by a
utility output (PO) (for example, a door). These codes are used only
to operate a utility output.