01/2022
Page 62
5IN2933
4.
At
Activities
press
OK.
5.
Scroll to
Config SW,
and then press
OK;
either CS CONNECT or ENABLE CS displays:
•
[If ENABLE CS displays]:
The system is
not
currently configured to allow the
technician/installer to access the CS. For you to authorize the technician/installer a
one-time access to the CS, press
OK,
scroll to
CS Connect
, and then proceed to step
6.
•
[If CS CONNECT displays]:
The system is currently configured to allow the
technician/installer to access to the CS. Proceed to step 6.
6.
At
CS Connect
press
OK.
7.
Scroll to the communication channel that the technician/installer computer will utilize to
communicate with the system (
IP or GSM
).
8.
Press
OK;
DONE displays, and the technician/installer now has a 1-hour time limit to
perform a CS reset of the system.
Disabling Smoke/Heat Detectors after Alarm Activation
After a fire alarm, the Grand Master can disable the activated smoke/heat detector(s) in the
system for an installer-set interval of up to 90 seconds in order to reset the detectors for
normal operation.
➢
To disable a fire alarm:
1.
At the keypad, enter your Grand Master code, and then press
OK
.
2.
At
Activities
press
OK.
3.
Scroll to
Advanced
and then press
OK.
4.
At
Switch Aux
press
OK;
the keypad beeps and the smoke/heat alarms are disabled.
5.
You may need to repeat this procedure until the detectors no longer detect any
remaining smoke or heat.