Charging of a Pb battery
Set up the charge current on the left and the nominal voltage on the right.
The range of current is 0.1- 5.0A, and the voltage should match the battery being charged.
Press the button for more than 3 seconds to start charging.
This screen displays the real-time charging status.
Press the button to end the program.
Pb (lead-sulphuric acid) battery program
This program is only suitable for charging a Pb (lead-acid) batteries with nominal voltage from 2 to 20V. A Pb
(lead-acid) battery is completely different to a NiCd / NiMH battery. These batteries can only deliver current lower in
comparison to their capacity. The same restriction applies to the charging process.
Consequently, the optimum charge current can only be 1/10 of the capacity. A Pb battery can not be fast-charged.
Please follow the instructions provided by the battery manufacturer. You can press the button to make it flash and
alter the value of the parameters using or the buttons, press the button to store the value.
Note:
Only charge PB batteries in a well ventilated area.