14
Input Power Low
Cut-Off
11.0v
Watt Limit (W)
CHG:
50
When the charge process starts, the integrated safety timer starts to run simultaneously. If an
error is detected or the termination circuit can not detect weather the battery is fully charged
or not, this function is programmed to prevent extreme overcharging. Please refer to the
statement below to calculate the timer you set.
The program provides, a maximum capacity protection function. If the Delta-peak voltage
can not be detected or the safety timer does not time out, the charge process will stop
automatically, when the battery reaches the user-set maximum charge capacity.
This function monitors the voltage of the DC input battery used to power this charger. If the
voltage is lower than the set value, the program will end forcibly to protect the input battery.
This setting sets the amount of beeps the charger speaker plays when the selected charge
function completes.
The beep is to confirm user operation every time a button is pressed.
The beep or melody sounds at various times during operation to confirm different mode
changes. This function can be switched on or off.
You can set a Watt limit for the charge rate between 30W and 50W.