Appendix B
Page B-1
Appendix B:
Controller Parameters
Parameters for PXR-4 Controllers
This instruction applies to the Fuji Electric PID
Controller with Fuzzy Logic, Model PXR-4 used
on the Neutec
™
J-2
r
casting machine.
NOTE: If you have a PXW-4 refer to page B-3 for
parameter settings
These instructions are used to improve the
heating speed to set-point, improve set-point
stability, and reduce overshoot in the event the
cast point (set-point) is missed. Additionally, the
machine operation has been programmed to
use the “cast on the way up” method applied on
the larger Neutec
™
J-series machines. The
programming uses the full capabilities of the
Fuji temperature controller including the Fuzzy
Logic feature, alert indicator light, and variable
balance adjustment.
Controller face
Purpose
The purpose of this procedure is to reset or
verify that the controller parameters are correct
for the desired temperature in °C and °F.
Open and Set dSP Factory Settings
1. Unplug the thermocouple and turn on the
J-2
r
. The SV light comes on and the set-point
value is displayed.
2. Press the “SEL” button for 6 seconds until:
“Su-L” displays in the upper row.
3. Press the down arrow (
∨
) until you see
“dSP1” on the display.
4. Push “SEL.” Press the up or down arrow
(
∧
or
∨
) until “255” is displayed (see dSP
factory settings chart below).
5. Push “SEL” once to enter value for dSP1.
6. Push the down arrow to access the next
parameter, dSP2.
Display Setting
dSP1 255
dSP2 255
dSP3 113
dSP4
44
dSP5 192
dSP6
255
dSP7 255
dSP8 255
dSP9 159
dP10 255
dP11 243
dP12 225
dP13 127
dSP factory settings, open
7. Repeat steps 3–6 using the dSP factory
settings chart (above) to enter factory
settings.