SS850 Freestanding IM
ELECTRICAL SUPPLY
Socket Outlet
Where a power point is used it
MUST
be 230 V, rated at 10A and
MUST
be earthed. This power point
MUST NOT
be located above the heater.
Alternatively the appliance can be direct wired if the power supply is to be
concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
⑨
which exits the appliance from the rear panel at the lower right when
viewed from the rear.
Direct Wired Installations
Alternatively the appliance can be direct wired with an isolation switch if so
required.
A qualified electrician will need to be consulted where a direct wired installation is required.
Any such installation
MUST
comply with the requirements of AS/NZS 5601, AS/NZS 3000 and
any other relevant local regulations.
IMPORTANT
9
WARNING
The power cord is not fire rated and
MUST NOT
come into contact with the unit. If the power
cord is damaged, it
MUST
be replaced by a licensed tradesperson. This must be a genuine
replacement part available from Rinnai.
SUPPLY CONNECTIONS