Rinnai 30
SS850 Freestanding IM
GENERAL INFORMATION
Step 1. Unpack the Fascia
For commissioning, the control panel located on the fascia will need to be connected to the communication cable
of the heater engine.
Remove all packaging materials and check all components for damage. If
ANY
damage is evident
DO NOT
install or operate this appliance. Contact your supplier for advice.
Step 2. Connect Push Button Control
Carefully pick up fascia assembly, and position the fascia close to the heater engine.
Connect the RJ45 Cable and Plug
(A)
into the socket
(B)
located on the front of the heater (this connects the
push button control panel via a communications cable to the heater engine's control box).
Step 3. Switch on the Electricity Supply
WARNING
230 VOLTS, RISK OF ELECTRICAL SHOCK!
Installation and commissioning
MUST
be carried out
ONLY
by an Authorised person.
Wiring inside this appliance may be at 230V potential, when performing the commissioning, the
appliance electrical power will need to be connected. Exercise
CAUTION
as there is potential for
electric shock from the exposed wiring and circuitry.
DO NOT
leave the appliance unattended
when power is connected and the panels are removed.
Step 4. Commission the Appliance
WARNING
DO NOT
test for gas leakage with an open flame.
The gas type codes and gas pressures for this appliance
MUST
be checked and set in
accordance with these instructions when the appliance is installed,
OR
after the replacement of
any component or reassembly after service.
Burner gas pressures and gas types are factory set.
The location of the gas control is in the air gap at the lower right hand side of the appliance.
The location of the data plate is on the base plate of the heater engine within the air gap on the right hand side of
the appliance
(C)
.
B
A
C
COMMISSIONING