rinnai new Zealand Limited
E-Frost Solar Collector Split System
install manual: 11497-a
17
mounting collectors on a metal roof
fit
collectors
7.
To assist in fitting the collectors there are a series of m5 threaded holes
along the mounting rails. in the solar collector fittings kit are m5 fasteners.
These should be inserted into the holes in the rail before the collectors are
fitted. These will act as ‘stoppers’.
Fit the collectors into the mounting rails. The stoppers will position the
panels at the right height for the slots to align so the mounting fasteners
can insert easily. The stoppers should be removed after the collectors are
fitted.
fit
additional
collectors
8.
Fit the first collector between the mounting brackets using fasteners
supplied, do not fully tighten at this point. Fit the collector connectors
for two or three panel systems to the first panel. Fit second collector by
inserting the header tubes into the connectors and attach the collector to
the rail with fasteners provided. Tighten fasteners on the first collector.
Firmly push collectors together, tighten connectors and then tighten
fasteners on second collector. repeat from step 7 if fitting a third panel.
Use lower holes