Electrical Requirements
(Installer shall provide electrical outlet
connections) Each unit has a 10 amp glass fuse
built into the wiring harness. Maximum load for
the N-Series Products should be less than 4 amps
in units without a circulation pump built-in or
connected to the unit.
N-Series Water Heaters requires 120 VAC, 60 Hz. 4 amp
properly grounded circuit power source when used without
a circulation pump connected to the unit.
Internal N-Series units: 75 watts normal operation; 2 watts
standby; 146 watts anti-frost protection.
External N-Series units: 71 watts normal operation; 2 watts
standby; 168 watts anti-frost protection.
Electrical Input Ratings
Electrical
Requirements