29
11/6/2018
© 2015 Rinnai America Corporation
PROPRIETARY and CONFIDENTIAL
Enhancing Lives By Changing The Way Water Is Heated
Next, ensure the water supply is turned off and pressure bled from system
1. Remove stainless steel clip stamped 18-28 on hot water outlet line. Pull line loose from fitting.
2. Remove stainless steel clip stamped 14-23 on bypass line. Pull line loose from fitting.
3. Remove stainless steel clip stamped 14-20 on inlet water line to secondary heat exchanger.
4. Removal condensate hose wire clamp and hose
Heat Exchanger Assembly Removal
1
2
3
4