To enter the maintenance monitor display mode:
Press and
hold
the DOWN arrow, in two seconds press the ON/OFF button at the same time. Release both buttons, First “01” will be
displayed followed by a display of the flow rate in GPM. Pressing the UP arrow will change the display to “02” followed by the output
water temperature and so on.
Code
Reading
Units
Description / Notes
01
Water Flow Rate
0.1 GPM
GPM through WH (decimal not shown).
02
Outgoing Temperature
Deg. Fahrenheit
Outgoing Water Temperature.
03
Combustion Hours
X100 Hours
Total Combustion Hours.
04
Combustion Cycles.
See chart to right
Total Combustion Cycles.
05
Fan Frequency
Hertz
Fan Motor Hertz (if operating).
06
Additional Controllers Connected
Connected or not
1 = Connected & 2 = Not connected
07
Water Flow Servo Position.
Position
0 = Partially Open / 1 = Open / 2 = Closed
08
Inlet Water Temperature.
Deg. Fahrenheit
Calculated Inlet Water Temperature.
09
Fan Current.
X10 mA
Fan Current Draw (if operating).
10
Total Bath Fill Volume.
Gallons
Volume of Water During Bath Fill Mode.
11
HEX Outlet Water Temperature
Deg. Fahrenheit
Heat exchanger outlet water temperature
12
Bypass Flow Control Position.
Degrees
Degrees of opening (if equipped)
15
Freeze Protection Temperature
Deg. Fahrenheit
Temperature of water in unit (indoor units)
17
Freeze Protection Temperature
Deg. Fahrenheit
Temperature of water in unit (outdoor units)
19
Total Pump Operating Hours
X100 hours
Pump operation time in hundreds of hours
20
Total Pump Cycles
See chart to right
Pump operation time in thousands of hours
21
Exhaust Temperature
Deg. Fahrenheit
Exhaust Temperature at Thermistor