6
VC
Series
Manual
Environment
Air
surrounding
the
water
heater,
ven
Ɵ
ng,
and
vent
termina
Ɵ
on(s)
is
used
for
combus
Ɵ
on
and
must
be
free
of
any
compounds
that
cause
corrosion
of
internal
components.
These
include
corrosive
compounds
that
are
found
in
aerosol
sprays,
detergents,
bleaches,
cleaning
solvents,
oil
based
paints/
varnishes,
and
refrigerants.
The
air
in
beauty
shops,
dry
cleaning
stores,
photo
processing
labs,
and
storage
areas
for
pool
supplies
o
Ō
en
contains
these
compounds.
Therefore
it
is
recommended
that
outdoor
models
be
used
for
these
loca
Ɵ
ons
where
possible.
The
water
heater,
ven
Ɵ
ng,
and
vent
termina
Ɵ
on(s)
should
not
be
installed
in
any
areas
where
the
air
may
contain
these
corrosive
compounds.
If
it
is
necessary
for
a
water
heater
to
be
located
in
areas
which
may
contain
corrosive
compounds,
the
following
instruc
Ɵ
ons
are
strongly
recommended.
IMPORTANT
CONSIDERATIONS
FOR:
Indoor/Internal
Water
Heaters
x
DO
NOT
Install
in
areas
where
air
for
combus
Ɵ
on
can
be
contaminated
with
chemicals.
x
Before
installa
Ɵ
on,
consider
where
air
has
the
ability
to
travel
within
the
building
to
the
water
heater.
x
Where
possible,
install
the
water
heater
in
a
sealed
closet
so
that
it
is
protected
from
the
poten
Ɵ
al
of
contaminated
indoor
air.
x
Chemicals
that
are
corrosive
in
nature
should
not
be
stored
or
used
near
the
water
heater.
Outdoor/External
Water
Heaters
and
Vent
Termina
Ɵ
ons
of
Indoor/Internal
Water
Heaters
x
Install
the
water
heater
as
far
away
as
possible
from
exhaust
vent
hoods.
x
Install
as
far
away
as
possible
from
air
inlet
vents.
Corrosive
fumes
may
be
released
through
these
vents
when
air
is
not
being
brought
in
through
them.
x
Chemicals
that
are
corrosive
in
nature
should
not
be
stored
or
used
near
the
water
heater
or
vent
termina
Ɵ
on.
Damage
and
repair
due
to
corrosive
compounds
in
the
air
is
not
covered
by
warranty.
Considera
Ɵ
on
of
care
for
your
water
heater
should
include
evalua
Ɵ
on
of
water
quality.
Water
that
contains
chemicals
exceeding
the
levels
below
a
ī
ect
and
damage
the
heat
exchanger.
Replacement
of
the
heat
exchanger
due
to
water
quality
damage
is
not
covered
by
the
warranty.
Maximum
Level
Total
Hardness
Up
to
200
mg
/
L
Aluminum
*
Up
to
0.2
mg
/
L
Chlorides
*
Up
to
250
mg
/
L
Copper
*
Up
to
1.0
mg
/
L
Iron
*
Up
to
0.3
mg
/
L
Manganese
*
Up
to
0.05
mg
/
L
pH
*
6.5
to
8.5
TDS
(Total
Dissolved
Solids)
*
Up
to
500
mg
/
L
Zinc
*
Up
to
5
mg
/
L
Determine
Installa
Ɵ
on
Loca
Ɵ
on
Water
Quality
*
Source:
Part
143
Na
Ɵ
onal
Secondary
Drinking
Water
Regula
Ɵ
ons
If
you
install
this
water
heater
in
an
area
that
is
known
to
have
hard
water
or
that
causes
scale
build
Ͳ
up
the
water
must
be
treated
and/or
the
heat
exchanger
fl
ushed
regularly.
When
scale
build
Ͳ
up
in
the
heat
exchanger
begins
to
a
ī
ect
the
performance
of
the
water
heater,
a
diagnos
Ɵ
c
code
“LC#”
will
display.
Flush
the
heat
exchanger
to
prevent
damage
to
it.
Scale
build
up
is
caused
by
hard
water
set
at
a
high
temperature.
Rinnai
provides
a
“Scale
Control
System”
that
o
ī
ers
superior
lime
scale
preven
Ɵ
on
and
corrosion
control
by
feeding
a
blend
of
control
compounds
into
the
cold
water
supply.
You
must
ensure
that
clearances
will
be
met
and
that
the
vent
length
will
be
within
required
limits.
Consider
the
installa
Ɵ
on
environment,
water
quality,
and
need
for
freeze
protec
Ɵ
on.
Requirements
for
the
gas
line,
water
lines,
electrical
connec
Ɵ
on,
and
condensate
disposal
can
be
found
in
their
respec
Ɵ
ve
installa
Ɵ
on
sec
Ɵ
ons
of
this
manual.
103000022
103000023
103000024
Installed
on
cold
water
line
supplying
1
tankless
water
heater
only
Whole
home
or
Light
Commercial
supply
Ͳ
ing
1
tankless
water
heater
Whole
home
supply
Ͳ
ing
2
tankless
water
heaters
or
1
tankless
in
Light
Commercial
Re
fi
ll
103000025
Re
fi
ll
103000026
Re
fi
ll
103000026