12) Removal of the Heat Exchanger
a. Remove two (2) of the termal fuse connectors.
(Red).
b. Pull off high tension lead and flame rod terminal.
(Yellow). Refer 5.
c. Remove 3 pin connector for igniter (White) and 4
pin connector for fan motor. (Black).
d. Pull off back pressure tube.
e. Remove mounting screws for manifold and gas
control. (2 screws). Refer 6.
a. Remove top panel sealing plate (2 screws).
b. Remove heat exchanger mounting screws.
(2 screws).
a. Remove heat exchanger mounting screws. (2
screws).
b. Remove inlet water connection tube (1 screw).
c. Remove outgoing water connection tube. (1 screw).
d. Take out heat exchanger.