Flueing Options
Flueing Options
Direct Flueing with Wall Terminal:
(Fig.1)
b)
Extended Direct Flueing with Wall Terminal:
(Fig.2)
c)
Vertical Flueing with Roof Terminal
(Fig.3)
Use
combinations of
fixed
and
adjustable
flue lengths to position
the installation, as flue
components can
NOT
be cut to size.
Ensure a 3° fall to
the flue terminal.
Important Installation Notes:
The components of this flueing system
CAN NOT BE
CUT
use telescopic components to achieve the required
length.
The flue system MUST be installed to comply with
AS5601/AG601 Clause 5.13.
Ensure that positioning of the flue terminal complies with
the requirements of AG5601/AG601.
Warning:
The flue
products can reach temperatures above 200°C. The flue
terminal is to terminate in a location, not to cause a
nuisance.
The Rinnai REU V1616WF is a fan-assisted appliance;
use the fan-assisted clearances in AS5601/AG601
Clause 5.13.6.5
All Flue MUST be supported and be independent of the
appliance in accordance with AS5601/AG601 Clause
5.13.4.2 and 5.13.4.3.
Ensure the appliance can be removed without causing
movement or displacement of the flue, as per
AS5601/AG601 clause 5.13.4.1. Telescopic components
extended to a minimum of 55mm can be used as a slip
socket.
Caution:
The “O” Rings in all components are pre-
greased; ensure they are not damaged when joining.
When preparing the wall and ceiling penetrations, cover
the flue spigot to prevent debris from entering the
appliance.
The mounting brackets on the appliance can be adjusted
from 15mm to 50mm to allow for irregularities in the walls
and length of the flue components.
1.8 m t o floor
5
230
~
300
88
187
72 ~ 400
5
Ventilated spacer
120
The m aximum and minim um wall
depth is dependent on kit used.
*
*
(Fig.1)
(Fig.3)
(Fig.2)
a)
Summary of Contents for REU-V1616WF
Page 19: ...Infinity REU V1616WF 14 Issue 1 21 11 03 Rinnai 7 Cutaway Diagram ...
Page 20: ...Infinity REU V1616WF 15 Issue 1 21 11 03 Rinnai 8 Operational Flow Chart ...
Page 25: ...Infinity REU V1616WF 20 Issue 1 21 11 03 Rinnai 12 Wiring Diagram ...
Page 47: ...Infinity REU V1616WF 42 Issue 1 21 11 03 Rinnai 20 Exploded Diagram ...
Page 48: ...Infinity REU V1616WF 43 Issue 1 21 11 03 Rinnai ...
Page 49: ...Infinity REU V1616WF 44 Issue 1 21 11 03 Rinnai ...
Page 50: ...Infinity REU V1616WF 45 Issue 1 21 11 03 Rinnai ...
Page 54: ...Infinity REU V1616WF Issue 1 21 11 03 Rinnai Notes ...