16. Component and Circuit Checks
1. Combustion Fan Circuit
Check the Motor
Check the combustion fan if the error indicator displays “61”.
Measure voltages between Black and Red of the PCB connector (A
1
).
Normal:
DC15~46V (when fan ON)
DC0V (when fan OFF)
If normal proceed to check the rotation sensor
Faulty:
Replace PCB
Check for the Fan Rotation Sensor
a.)
Measure voltages between Black and Yellow of connector (A
1
).
Normal:
DC11~13V
If normal proceed to b.).
Faulty:
Replace PCB.
b.)
Measure voltages between Black and White of connector (A
1
).
Normal:
DC2~10V
If normal proceed to Sparker Circuit 2.
Faulty:
Replace Combustion Fan.
2. Sparker Circuit
a.)
Measure voltages between Grey and Grey of connector (C
1
).
Normal:
AC90~110V
If Normal proceed to b.).
Faulty:
Replace PCB.
b.) Disconnect connector (J
6
) and measure resistance between both terminals of the sparker.
Normal:
1M
Ω
If not sparking, adjust or replace ignition plug.
Faulty:
Replace Sparker.
Summary of Contents for REU-V1616WF
Page 19: ...Infinity REU V1616WF 14 Issue 1 21 11 03 Rinnai 7 Cutaway Diagram ...
Page 20: ...Infinity REU V1616WF 15 Issue 1 21 11 03 Rinnai 8 Operational Flow Chart ...
Page 25: ...Infinity REU V1616WF 20 Issue 1 21 11 03 Rinnai 12 Wiring Diagram ...
Page 47: ...Infinity REU V1616WF 42 Issue 1 21 11 03 Rinnai 20 Exploded Diagram ...
Page 48: ...Infinity REU V1616WF 43 Issue 1 21 11 03 Rinnai ...
Page 49: ...Infinity REU V1616WF 44 Issue 1 21 11 03 Rinnai ...
Page 50: ...Infinity REU V1616WF 45 Issue 1 21 11 03 Rinnai ...
Page 54: ...Infinity REU V1616WF Issue 1 21 11 03 Rinnai Notes ...