10) Removal of the
Water Flow Servo
a. Pull off the water flow sensor connector. (Black,
Yellow, Red).
b. Remove screw to fit the inlet water tube with heat
exchanger (1 screw).
• Unlock mounting bracket and pull off inlet water
tube (Take care with O ring).
c. Remove screws of inlet water connection and water
flow servo (4 screws).
d. Pull off 6 pin connector of the water flow servo.
(Red, Black, Yellow, Brown, Blue).
e. Take out water flow servo with sensor.
• Water Flow servo with flow sensor.
11) Removal of the Fan Motor
a. Remove inlet water tube. (1 screw).
b. Remove combustion fan mounting screws and pull
off. (3 screws).
c. Remove the 4 pin connector.
• Fan and Fan motor.