Infinity REU-V1616WF
- 32 -
Issue 1 - 21/11/03 ©Rinnai
*Note 3
Water Flow Servo Positioning
To return to normal operation
•
Press the ON/OFF button again while holding down the Water Temperature "DOWN" (Cooler)
button.
To return to normal operation.
•
Press the ON/OFF button again while holding the Water Temperature “UP” (Hotter) button.
•
This feature will automatically shut down after 3 minutes.
07
Water flow servo present recognising positioning
None
0~2
*Note 3
Servo Position
Open
Centre
Closed
Display
“1”
“0”
“2”
08
Inlet water temperature
(PCB recognition value)
(Example 25 = 25°C)
°C
0~999
09
Hot water fan current flow value
(Example 6 x 10 = 60 mA)
10 mA
0~999
10
Bath fill (Not applicable)
Error History
To Display Error Memory (History)
(This feature will show the last 10 faults in sequence)
1. Turn off at the ON/OFF button. (This can be done during
operation)
2. Press the ON/OFF button while holding the Water Temperature
"UP" (Hotter) button.
•
The Sequence will be shown in the Water Temperature display.
•
Error Code will be shown in the Clock display. (See service
Manual for error codes).
•
Where there are less than a total of 9 errors, "FFF" or " - - " will
be displayed in the Clock display.
Summary of Contents for REU-V1616WF
Page 19: ...Infinity REU V1616WF 14 Issue 1 21 11 03 Rinnai 7 Cutaway Diagram ...
Page 20: ...Infinity REU V1616WF 15 Issue 1 21 11 03 Rinnai 8 Operational Flow Chart ...
Page 25: ...Infinity REU V1616WF 20 Issue 1 21 11 03 Rinnai 12 Wiring Diagram ...
Page 47: ...Infinity REU V1616WF 42 Issue 1 21 11 03 Rinnai 20 Exploded Diagram ...
Page 48: ...Infinity REU V1616WF 43 Issue 1 21 11 03 Rinnai ...
Page 49: ...Infinity REU V1616WF 44 Issue 1 21 11 03 Rinnai ...
Page 50: ...Infinity REU V1616WF 45 Issue 1 21 11 03 Rinnai ...
Page 54: ...Infinity REU V1616WF Issue 1 21 11 03 Rinnai Notes ...