![Rinnai REU-V1616WF Service Manual Download Page 18](http://html1.mh-extra.com/html/rinnai/reu-v1616wf/reu-v1616wf_service-manual_1463120018.webp)
Infinity REU-V1616WF
- 13 -
Issue 1 -
21/11/03
©Rinnai
Connecting Three Controllers
1. Isolate the power supply.
2. Remove the front cover from the Appliance (4 screws) as shown in fig.1.
3. Cut the spade connectors from 2 of the controller cables to be
connected to the appliance (4 spade connectors should be cut
off) and discard. Connect the wires from these two cables and
terminate into two new spade connectors as shown in fig.3.
Spade connectors are available from your local electrical
component retailer.
4. Thread the 3 cables through the cable access hole at the base
of the appliance.
5.
Ensure the position of the terminals for controls
shown on
the Printed Circuit Board
COVER
. Connect the 4 spade
connectors to the terminals on the P.C.B. (fig 2). Polarity is
not important. Either wire colour can be connected to either
terminal.
Connect cable clamp around controller wiring to provide
cord anchorage.
6. Replace cover of the appliance, ensuring that the screw with
the star washer is placed at the bottom right hand corner for
earthing purposes.
If the front cover of the appliance contains the following text, "THIS APPLIANCE
DELIVERS WATER NOT EXCEEDING 50° C IN ACCORDANCE WITH AS 3498"
IF YES: No further action required.
IF NO:
You will need to program the Kitchen controller to
enable selection of temperatures higher than 50º C.
STEP 1:
For the controller in the KITCHEN only, press and hold the
'Transfer' and 'On/Off' buttons simultaneously (see fig 1.)
until a 'beep' is heard (approximately 5 seconds).
STEP 2:
When the controller fitted in the KITCHEN is switched on, it should be possible to select temperatures
higher than 50º C. If not, repeat Step 1.
Note:
• If the kitchen controller is replaced, repeat STEP 1 above for the replacement controller
• If the kitchen controller is swapped with another controller (for example, the controller fitted
in a bathroom), repeat STEP 1 for the controller moved from the kitchen to the bathroom.
Then perform STEP 1 for the controller moved from the bathroom to the kitchen.
,
fig. 2
TERMINALS
FOR CONTROLS
REMOTE CONTROL
CABLE
CABLE CLUMP
fig. 3
Newspade connectors
Cable wires
Cable wires
Remote control cables
fig.
1
Summary of Contents for REU-V1616WF
Page 19: ...Infinity REU V1616WF 14 Issue 1 21 11 03 Rinnai 7 Cutaway Diagram ...
Page 20: ...Infinity REU V1616WF 15 Issue 1 21 11 03 Rinnai 8 Operational Flow Chart ...
Page 25: ...Infinity REU V1616WF 20 Issue 1 21 11 03 Rinnai 12 Wiring Diagram ...
Page 47: ...Infinity REU V1616WF 42 Issue 1 21 11 03 Rinnai 20 Exploded Diagram ...
Page 48: ...Infinity REU V1616WF 43 Issue 1 21 11 03 Rinnai ...
Page 49: ...Infinity REU V1616WF 44 Issue 1 21 11 03 Rinnai ...
Page 50: ...Infinity REU V1616WF 45 Issue 1 21 11 03 Rinnai ...
Page 54: ...Infinity REU V1616WF Issue 1 21 11 03 Rinnai Notes ...