Infinity REU-3203W
- 34 -
©Rinnai
15.Bypass Servo Circuit 15.
a.)
Disconnect relay connector (B
1
) and
measure resistance.
If normal, proceed to
b
.
Faulty:
Replace PCB.
b.)
Measure working voltage while relay
connector (B
1
) is connected.
Faulty:
Replace Bypass Servo.
16.Remote Control
Check the voltage between the 2-core remote
control cable.
Measure the voltage between terminals on
the remote control terminal (H
1
).
Normal:
DC 11~13V
If normal, replace the remote control
after confirming that the cable hasn’t
been damaged or shorted.
Faulty:
Because normal voltage is not
given due a short circuit, despite the
PCB being in normal state, check Water
Flow Servo circuit.
If solution is not given from the above
replace PCB.
Normal
CN
Wire Colour
Value
B
1
Br - W
O - W
Y - W
R - W
GND
15~35
Ω
Normal
CN
Wire Colour
Value
B
1
Br - W
O - W
Y - W
R - W
GND
DC 2~6V
Summary of Contents for INFINITY REU-3203W
Page 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Page 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Page 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Page 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU 3203W 50 Rinnai...
Page 56: ...Infinity REU 3203W 51 Rinnai...
Page 57: ...Infinity REU 3203W 52 Rinnai...
Page 61: ...Infinity REU 3203W Rinnai Notes...
Page 62: ...Infinity REU 3203W Rinnai...
Page 63: ...Infinity REU 3203W Rinnai...