16. Component and Circuit Checks
1. Combustion Fan Circuit
Check the Motor
Check the combustion fan if the error
indicator displays “61”.
Measure voltages between Black and Red of
the PCB connector (C).
Normal:
DC7~45V (when fan ON)
DC0V (when fan OFF)
If normal proceed to check the rotation
sensor
Faulty: Replace PCB
Check for the Fan Rotation Sensor
a.)
Measure voltages between Black and
Yellow of connector (C).
Normal:
DC10~14V
If normal, proceed to
b
.
Faulty:
Replace PCB.
b.)
Measure voltages between Black and
White of connector (C).
Normal:
DC2~9V
If normal, proceed to Sparker Circuit 2.
Faulty:
Replace Combustion Fan.
2. Sparker Circuit
a.)
Measure voltage between Grey and Black
of connector ( J
6
).
Normal:
AC90~110V
If normal, proceed to
b
.
Faulty:
Replace PCB.
b.)
Disconnect connector ( J
6
) and measure
resistance between both terminals of the
sparker.
Normal:
> 1M
Ω
If not sparking, adjust or replace ignition
plug.
Faulty:
Replace Sparker.
Summary of Contents for INFINITY REU-3203W
Page 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Page 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Page 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Page 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU 3203W 50 Rinnai...
Page 56: ...Infinity REU 3203W 51 Rinnai...
Page 57: ...Infinity REU 3203W 52 Rinnai...
Page 61: ...Infinity REU 3203W Rinnai Notes...
Page 62: ...Infinity REU 3203W Rinnai...
Page 63: ...Infinity REU 3203W Rinnai...