Infinity REU-3203W
- 30 -
©Rinnai
6. Thermal Fuse Circuit .
Check the Thermal Fuse.
Disconnect relay connector (F
1
) and measure
resistance between Red and Red.
Normal:
< 1
Ω
If normal, replace PCB.
Faulty:
Replace Thermal Fuse if after
confirming there is no damage to the
appliance.
7. Overheat Switch Circuit.
Measure resistance between Overheat Switch
terminals (F
2
).
Normal:
< 1
Ω
If normal, replace PCB.
Faulty:
Replace Overheat Switch.
Note:
If Thermal fuse or Overheat Switch
were faulty.
a.) Check heater for damage
b.) Confirm gas type and combustion
dipswitch settings
c.) Confirm test point pressure.
8. Water Flow Sensor
a.)
Measure voltage between Red - Black of
relay connector (E
3
).
Normal:
DC 11~13V
If normal, proceed to
b
.
Faulty:
Replace PCB.
b.)
Measure voltage between Yellow - Black
of relay connector (E
3
).
Normal:
DC 4~7V
If normal, proceed to 2.
Faulty:
Replace water flow sensor.
Note:
For controller readout of water flow
whilst operational refer maintenance monitor
(chapter
17) No. 1.
Summary of Contents for INFINITY REU-3203W
Page 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Page 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Page 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Page 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Page 55: ...Infinity REU 3203W 50 Rinnai...
Page 56: ...Infinity REU 3203W 51 Rinnai...
Page 57: ...Infinity REU 3203W 52 Rinnai...
Page 61: ...Infinity REU 3203W Rinnai Notes...
Page 62: ...Infinity REU 3203W Rinnai...
Page 63: ...Infinity REU 3203W Rinnai...